HIKVISION DeepinView DS-2CD6425G0/F Series User Manual page 150

Table of Contents

Advertisement

window, and right click to finish the area drawing.
Notes:
 Polygon area (4~10 sides) sides is supported.
 If the live view is stopped, there is no way to draw the configured area.
4. Click Save to save the settings.
 Advanced Configuration
Face Capture Version: It lists the version of the algorithms library.
Configure the following parameters according to your actual environment.
Detection Parameters:
Generation Speed [1~5]: The speed to identify a target. The higher the value, the
faster the target will be recognized. Setting the value quite low, and if there was a face
in the configured area from the start, this face will not be captured. It can reduce the
misinformation of the faces in the wall painting or posters. The default value of 3 is
recommended.
Capture Times [1~10]: Refers to the capture times a face will be captured during its
stay in the configured area. The default value is 1.
Sensitivity [1~5]: The sensitivity to identify a target. The higher the value, the easier