Panasonic FV-10VEC2R Installation And Operating Instructions Manual page 10

Energy recovery ventilator
Hide thumbs Also See for FV-10VEC2R:
Table of Contents

Advertisement

DUCTWORK
Return
air
Outdoors
Note
(1)Must have 2-3 feet of straight duct run from all duct attachment points on the
ERV. Do not use any elbows or other peripheral pieces inside of 2-3 feet when
attaching duct runs to the ERV.
(2)Unit is normally balanced on high speed with the furnace blower on.
(3)A minimum separation of 40 inches (1 m) is recommended between the two
direct connections.
(4)The exhaust air connection shall be upstream of the supply air connection to
prevent exhausting any fresh air.
(5)The distance between two outdoor hoods please see P.12.
(6)The airflow must be confirmed on site using the balancing procedures found in
P.14.
- Partially dedicated ducted installation
Method
This method draws return air from specific points in the house and supplies an equal
amount of outside air into the return air duct of the air furnace. (Fig.9 & Fig.10)
Return air ducts of ERV should be installed in areas of the home where the poorest indoor
air quality exists (bathroom and kitchen).
The air furnace blower should be running when the ERV is operating to evenly distribute the
outside air throughout the house.
Note
(1)The ERV unit must be balanced.
(2)It is mandatory that HVAC/AHU signal cord be
connected.
(3)Check local codes and authority having
jurisdiction for acceptance.
10
40" (1 m) Min.
Dampers for
balancing
airflows
OA
EA
Return air
36"
(914 mm)
Min.
RA
SA
Air
furnace
Fig.8
Fig.9