Aprilaire S86W MUPR Safety & Installation Instructions page 19

Wi-fi thermostat with iaq
Hide thumbs Also See for S86W MUPR:
Table of Contents

Advertisement

TABLE 5 – FRESH AIR VENTILATION SYSTEM SETTINGS
System setting
Description
High Vent
Sets high ventilation temperature
Temperature
lockout limit (Only available if High Vent
Limit
Temperature Limit is set to Enabled)
Low Vent
Enables low ventilation temperature
Temperature
lockout limit (Only available if an outdoor
Limit
sensor option is enabled)
Low Vent
Sets low ventilation temperature
Temperature
lockout limit (Only available if Low Vent
Limit
Temperature Limit is set to Enabled)
Selects if ventilation forces the fan on
HVAC Fan with
(Yes with high and low limits is only
Vent?
available if an outdoor sensor option is
enabled)
Enables high mixing temperature (Only
High Mixing
available is HVAC Fan with Vent is set to
Temperature
Yes with high and low limits)
Sets the high mixing temperature (Only
High Mixing
available if High Mixing Temperature is set
Temperature
to Enabled)
36
Factory default setting (bold)
and setting range
100°F (38°C)
85°F to 105°F (29°C to 41°C)
Disabled
Enabled
10°F (-12°C)
-10°F to 40°F (-24°C to 6°C)
Yes
Yes with high and low limits
No
Disabled
Enabled
80°F or (26°C)
60°F to 105°F (14°C to 41°C)
TABLE 5 – FRESH AIR VENTILATION SYSTEM SETTINGS
System setting
Description
Enables low mixing temperature (Only
Low Mixing
available is HVAC Fan with Vent is set to
Temperature
Yes with high and low limits)
Sets the Low mixing temperature (Only
Low Mixing
available if Low Mixing Temperature is set
Temperature
to Enabled)
Fresh Air
Enable or disable the Service Fresh Air
Reminder
message
Select number of months between
Recurrence
Service Fresh Air messages
Factory default setting (bold)
and setting range
Disabled
Enabled
40°F (6°C)
0°F to 50°F (-18°C to 12°C)
Disabled
Enabled
12 Months
1 to 12 Months
37