TABLE 1 – HVAC INSTALLER SYSTEM SETTINGS
System setting
Description
Number of
Select number of compressor stages
Compressor
(Heat Pump mode only)
Stages
Number of Auxiliary
Select number of auxiliary heat
Heat Stages
stages (Heat Pump mode only)
Number of Stages
Select number of heat stages (Heat/
of Heat
Cool mode only)
Number of Stages
Select number of cool stages (Heat/
of Cool
Cool mode only)
Non Programmable hides all
Programmable
scheduling features
Selects how the external temperature
sensor terminals (T1 & T2) are being
Wired Temperature
used Choose Outdoor for a wired
Sensor Installed?
outdoor sensor or Remote/Remote
Average for a wired indoor sensor
20
Factory default setting (bold)
and setting range
One
Two
One
Two
One
Two
One
Two
Programmable
Non Programmable
Outdoor
Remote
(Onboard sensor disabled)
Remote Average
(Average with onboard sensor)
No
(No external sensor connected)
TABLE 1 – HVAC INSTALLER SYSTEM SETTINGS
System setting
Description
Select where the outdoor temperature
Outdoor
data comes from (This option is not
Temperature Data
available if you are using the wired
Provided From?
outdoor temperature sensor)
Select No to skip the rest of the
Advanced HVAC
Settings?
thermostat settings
Selects if the thermostat connects
Connection Type
with an automation system or an
AprilAire account
Progressive
Enables or disables progressive
Recovery
recovery
Select if the Heat Blast option is
Display Heat Blast?
displayed
Amount of heating when Heat Blast is
Heat Blast Offset
initiated
Factory default setting (bold)
and setting range
Web
Automation
(for home automation config only)
None
Wireless
(Wireless outdoor sensor)
No
Yes
AprilAire Cloud
Automation System
Disabled
Enabled
No
Yes
3°F (1.5°C)
4°F (2°C)
5°F (25°C)
21