Aprilaire S86W MUPR Safety & Installation Instructions page 18

Wi-fi thermostat with iaq
Hide thumbs Also See for S86W MUPR:
Table of Contents

Advertisement

TABLE 5 – FRESH AIR VENTILATION SYSTEM SETTINGS
System setting
Description
Calculated
Minutes Per
Displays the Fresh Air Time calculated
Hour
Manual adjustment of Calculated Minutes
Override
per Hour
Selects how the external temperature
Wired
sensor terminals (T1 & T2) are being used
Temperature
Choose Outdoor for a wired outdoor
Sensor
sensor or Remote/Remote Average for a
Installed?
wired indoor sensor
Outdoor
Select where the outdoor temperature
Temperature
data comes from ( This option is not
Data Provided
available it you are using the wired
From?
outdoor temperature sensor)
34
Factory default setting (bold)
and setting range
None
Range 6 to 60 Minutes
(Calculated Minutes per Hour)
Range 6 to 60 Minutes
Outdoor
Remote
(Onboard sensor disabled)
Remote Average
(Average with onboard sensor)
No
(No external sensor connected)
Web
Automation
(for home automation config only)
None
Wireless
(Wireless outdoor sensor)
TABLE 5 – FRESH AIR VENTILATION SYSTEM SETTINGS
System setting
Description
Selects if ventilation is disabled when the
High Vent RH
indoor RH exceeds the indoor RH limit
Limit
(Only available if Fresh Air Setup is set to
Comfort)
Sets the ventilation indoor RH lockout
High Vent RH
limit (Only available if High Vent RH Limit
Limit
is set to Enabled)
Selects if ventilation is disabled when the
Low Vent RH
indoor RH exceeds the indoor RH limit
Limit
(Only available if Fresh Air Setup is set to
Comfort)
Sets the ventilation indoor RH lockout
Low Vent RH
limit (Only available if Low Vent RH Limit is
Limit
set to Enabled)
High Vent
Enables high ventilation temperature
Temperature
lockout limit (Only available if an outdoor
Limit
sensor option is enabled)
Factory default setting (bold)
and setting range
Disabled
Enabled
55%
45% to 70%
Disabled
Enabled
20%
10% to 30%
Disabled
Enabled
35