Summary of Contents for Watts HF scientific Air Sentinel II 110010
Page 1
IOM-HF-Air Sentinel II-100038B Installation and Operation Manual Air Sentinel™ II Purge Controller Model Air Sentinel™ II 110010 WARNING Read this Manual BEFORE using this equipment. Failure to read and follow all safety and use information can result in death, serious personal injury, property damage, or damage to the equipment.
Specifications Enclosure 316 Stainless Steel Mounting 10 Studs, ¼" -20 Display Indicators Two Bi-color (Red & Green ) LEDs Alarms Two 1 Form A (SPST-NO) Relay Contacts Rated 2A at 125VAC or 2A at 30VDC Control Output One 2 Form A (SPDT-NO) Relay Internally Connected To Mains Contacts Rated 2A at 240VAC Electrical Connections One Removable Power Input, Once removable Power Output...
1.0 Safety 2.0 Orientation This manual contains basic instructions that must be followed during From the diagram below, the major components can be located. the installation, commissioning, operation, care and maintenance of the instrument. The safety protection provided by this equipment may be impaired if it is commissioned and/or used in a manner not described in this manual.
3.0 Installation and Commissioning 3.4 Electrical Alarm Connections 3.1 Air Supply Three relay (1 Form A) alarm connections are supplied that can be used This instrument requires water free and oil free air, Dry Air, Particles to indicate an Alarm condition under the following modes of operation: <5u, ISA Grade Hydrocarbon Free.
4.2 Indicator Lamps The Air Sentinel II indicator lamps are a very quick way to determine to operation of the controller and thus the safety condition of the connected instrument or equipment. The Air Sentinel II has two LEDs that can be either RED or GREEN. : This lamp indicates if the minimum enclosure pressure is met : This indicates if the timer is enabled...
6.0 Instrument Labels The following labels should be applied to the outside of the enclosure: Purpose Location Label Product name and Front of Air Sentinel II certifications Serial number, Front of Air Sentinel II manufacturer, part number, power rating, CE & UL marking Warning and Front of Air Sentinel II PRESSURIZED ENCLOSURE...
7.0 Limited Warranty Watts Regulator Co. (the “Company”) warrants each ballast water market instrument product to be free from defects in material and workmanship under normal usage for a period of two (2) years from first use or three (3) years from date of the Company’s invoice from the original sale of the product, whichever occurs first.