1. Type 1 hardware
2. Type 2 hardware
3. Type 3 hardware
4. Type 4 hardware
5. (Type 1) 3/8–16 x 4 hex screw
6. (Type 2 & 3) 3/8–24 x 2 hex screw — Torque to 50–55 ft-lb
(68–75 N-m)
7. (Type 4) 3/8 whizlock nut — Torque to 30–35 ft-lb
(41– 47 N-m)
8. Spring disc washer (cone towards bolt head)
9. (Type 1) 3/8 whizlock nut and heavy flat washer — Torque
to 40–45 ft-lb (54–61 N-m)
10. (Type 2) 3/8 nyloc nut and heavy flat washer — Torque to
30–35 ft-lb (41–47 N-m)
11. (Type 3) 3/8 flanged nyloc nut without washer — Torque
to 30–35 ft-lb (41– 47 N-m)
12. (Type 4) 3/8 nyloc nut —Torque to 30–35 ft-lb (41– 47 N-m).

Servicing the Battery

WARNING
CALIFORNIA
Proposition 65 Warning
Battery posts, terminals, and related
accessories contain lead and lead compounds,
chemicals known to the State of California
to cause cancer and reproductive harm.
Wash hands after handling.
Important: The machine is shipped with a filled
lead acid battery.
1. Remove the battery cover from machine.
Figure 5
Charging the battery may produce explosive
gasses. Battery gasses can explode causing
serious injury.
• Keep sparks, flames, or cigarettes away from
battery.
• Ventilate when charging or using battery in
an enclosed space.
• Make sure venting path of battery is always
open once battery is filled with acid.
2. Check the voltage of the battery with a digital
voltmeter. Locate the voltage reading of the battery
in the table below and charge the battery for the
recommended time interval to bring the charge up
to a full charge of 12.6 volts or greater.
Important: Make sure the negative battery
cables are disconnected and the battery charger
used for charging the battery has an output of
16 volts and 7 amps or less to avoid damaging
the battery (see chart below for recommended
charger settings).
Voltage
Percent
Reading
Charge
12.6 or
100%
greater
12.4 – 12.6
75–100%
12.2 – 12.4
50–75%
12.0–12.2
25–50%
11.7–12.0
0–25%
11.7 or less
0%
4
DANGER
Maximum
Charging
Charger
Interval
Settings
No Charging
16 volts/7
Required
amps
30 Minutes
16 volts/7
amps
1 Hour
16 volts/7
amps
2 Hours
14.4 volts/4
amps
3 Hours
14.4 volts/4
amps
6 Hours or
14.4 volts/2
More
amps