Note 1: The system operates directly from 24 VDC ±20%. Power to the system must come from a
24VDC SELV power supply which meets the voltage interruptions and dip requirements of IEC 61496-1
(per section 4.3.2.2 and 5.4.3.2) and IEC 60204-1 (per section 4.3.3), Omron STI part number 42992 or
equivalent. The power supply size is dependent on the total current required by two solid-state safety
outputs and the auxiliary output should not exceed 1.35 A. Total system current requirements is the sum
of transmitter (285mA), receiver (450mA), OSSD1 (625mA), OSSD2 (625mA).
Note 2: 24 VDC is nominal. Actual voltage is dependent upon supply, V = Vsupply - 1V.
Note 3: When using a Omron STI-supplied 30 meter receiver cable the total load current is limited to
1.2A at 24V (nominal). See when using customer supplied cables.

Table 13-2 Response Time of MS/MSF4800 System

Minimum
Beam Count
0
17
72
127
181
236
Minimum
Beam Count
0
60
115
169
224
Note: Refer to Section 13 --
your system.
1 3 . 2 C
The table below lists the maximum specified lengths and wire gauges of the MS4800 input & output
signals.
Table 13-3 MS4800 Input & Output Signal Cable Lengths
OMRON Scientific Technologies Inc.
Buy: www.ValinOnline.com | Phone 844-385-3099 | Email: CustomerService@valin.com
ANSI R15.6-1999, ANSI B11.19-2003, OSHA 1910.217(c).
All systems have been EC type examined to the requirements of IEC
61496-1, -2 for a Type 4 ESPE. TUV Registration No.
BB600166650001. UL61496-1 & -2. IEC 61508 (SIL3)
Specifications subject to change
One Segment System
Maximum
Response Time (ms)
Beam Count
Normal
16
71
126
180
235
256
Three Segment System
Maximum
Response Time (ms)
Beam Count
Normal
59
114
168
223
256
Specifications and Additional Information
L
(C
A BL E
EN G THS
US TO ME R S UP PLI ED CA BLE S
MS4800
Signal Names
MS4800
OSSD 1 & 2
Receiver
Outputs
24 VDC Input
Power & Return
MS4800
24 VDC Input
Transmitter
Power & Return
Minimum
Beam Count
14
0
23
66
32
121
41
175
50
230
59
Minimum
Beam Count
23
0
32
54
41
109
50
163
59
218
to determine the number of beams in
Wire Gauge
2
22 AWG (0.32mm
)
wire
2
20 AWG (0.52mm
)
wire
2
22 AWG (0.32mm
)
wire
40
Two Segment System
Maximum
Response Time (ms)
Beam Count
Normal
65
23
120
32
174
41
229
50
256
59
Four Segment System
Maximum
Response Time (ms)
Beam Count
Normal
53
23
108
32
162
41
217
50
256
59
)
Specified Maximum Length
300mA load: 45 meter (147 ft)
625mA: 22 meter (72 ft)
1.8 Amp load: 12.5 meter (41 ft)
1 Amp load: 22 meter (72 ft)
0.3 Amp: 47 meter (150 ft)