Overview
The Network Station Power Supply
(P-NSPS-D) is a DIN rail mounted
power supply that powers up to
63 Paradigm stations or sensors over
the LinkConnect station
communication bus.
The Network Station Power Supply
consists of two components that must
be used together: the DIN rail Network Station Power Supply that powers the
station communication bus, and the DIN rail 48 VDC Power Supply that feeds
the DC power to it. This guide covers installation and basic setup of both
products.
Specifications
Note:
electrical equipment.
Environment
Ambient 0°C-50°C (32°F-122°F), 0-95% relative humidity (non-condensing)
Mounting
Vertically mount (only) on horizontal DIN rail (TS35 compatible).
Clearance
For best performance and to prevent overheating, leave a minimum clearance
between devices on the DIN rail. Clearance required: adjacent - 15 mm 
(0.6 in), above 40 mm (1.6 in), below 20 mm (0.8 in).
Important Safeguards
CAUTION:
ATTENTION :
contrôlé.
Installation must follow all national and local codes for
For use in a controlled environment.
Pour une utilisation dans un environnement
Corpora te He a dqua rte rs n Middleton, WI, USA | +1 608 831 4116
Globa l Offic e s n London, UK | Rome, IT | Holzkirchen, DE | Paris, FR | Hong Kong
Dubai, UAE | Singapore | New York, NY | Orlando, FL | Los Angeles, CA | Austin, TX
We b
etcconnect.com
Conta c t
etcconnect.com/contactETC
Trademark and patent info:
subject to change. ETC intends this document to be provided in its entirety.
7 1 8 2 M 2 1 0 0 Rev A Released 2021-08
| Support
support.etcconnect.com
| © 2021 Electronic Theatre Controls, Inc.
etcconnect.com/ip
| Product information and specifications

Advertisement

loading

Summary of Contents for ETC P-NSPS-D

  • Page 1 | © 2021 Electronic Theatre Controls, Inc. Trademark and patent info: etcconnect.com/ip | Product information and specifications subject to change. ETC intends this document to be provided in its entirety. 7 1 8 2 M 2 1 0 0 Rev A Released 2021-08...
  • Page 2 ETC Installation Guide P-NSPS-D Electrical 48 VDC DIN Rail Power Supply Accepts 100-240 VAC, 50/60 Hz input, and provides 48 VDC to the P-NSPS-D. Network Station Power Supply Note: This product is intended for use with a Listed and marked SELV/LPS or Class 2 supply.
  • Page 3 ETC Installation Guide P-NSPS-D combination of bus, star, loop, or home-run. The total combined length of a LinkConnect wire run using Belden 8471 may not exceed 500 m (1,640 ft), with a maximum distance of 400 m (1,312  ft) between any two devices. Note: All control wiring should be installed and terminated by a qualified installer and follow standard wiring installation practices.
  • Page 4: Installation

    Power Supply. a. Secure the DIN rail in place. b. For the P-NSPS-D, hook the top bracket over the DIN rail and pivot down until the bottom clip seats completely onto the rail. You will hear an audible click when the unit is fully seated.
  • Page 5: Display And Buttons

    ETC Installation Guide P-NSPS-D 5. Cut and install an ESD ground wire from the P-NSPS-D 48 VDC power connector to the shared ground used for the installed Paradigm stations. a. Measure and cut a ground conductor (typically a 2.5 mm (14 AWG)
  • Page 6: Led Status Indicators

    Errors that are present in the system will display on the Status screen and will automatically clear themselves if the condition is resolved. Error Description Resolution <name> Lost This P-NSPS-D has lost communication with the <P-ACP> <name> This P-NSPS-D has Unconnected...
  • Page 7 1. Turn off power (at the source) to the 48 VDC Power Supply. 2. Disconnect all wiring to the P-NSPS-D. 3. Grip the P-NSPS-D and in one motion, slide it straight up and pivot the top of the unit off of the DIN rail.
  • Page 8 ETC Installation Guide P-NSPS-D Menu Arch Control Status Station Power Supply # IP: 10.101.12.101 System OK P-ACP: Processor 2 v#.#.# Main Menu About IP Configuration About IP Configuration Manual IP: 100.100.100.99 Setup Version Info Subnet Mask: File Operations Host Processor 255.255.0.0...