Environmental Instruction

Packing

Boiler Plant Decommissioning

Operating Principle

PELLETTI XL boiler is designed first of all
for pellet burning. While choosing pellet boil-
ers it is necessary to clear up necessity in free
space, pellet storage and frequency of boiler
cleaning. Installation shall always be per-
formed

Technical Data

Power range:
Weight:
Water capacity:
Max. temperature:
Min. temperature:
Max. pressure:
Proof-test pressure:
15...30 kW
450 kg
220 L
110 ºC
0 ºC
1.5 bar
4.0 bar
Pelletti XL
3
Packing is made of 100 % waste materials.
Dispose of packing in accordance with local
waste disposal requirements.
The boiler shall be delivered to metal scrap
receiving points and electric components - to
receiving points of electric and electronic
components.
by qualified personnel knowing requirements
of official control authorities.
It is recommended to use energy accumula-
tors in combination with pellet burner as it
increases operating cycle, improves operating
level and reduces emissions.
Max. total capacity:
Voltage:
Frequency:
Protection class:
Furnace dimensions:
6.2 kW
230 V
50 Hz
IP 2X
height 750 mm
width 290 mm
depth 380 mm