Mitsubishi Electric CAHV-R450YA-HPB Installation & Operation Manual page 19

Hot water heat pump unit
Hide thumbs Also See for CAHV-R450YA-HPB:
Table of Contents

Advertisement

(2) Factory Switch Settings (Dip switch settings table)
SW
Function
1
2
3
4
5
Model setting
SW4
6
7
8
9
10 Model setting
1 Freeze-up protection setting
Scheduled operation
2
display
3 Model setting
4 Model setting
Recovery conditions after
5
forced stoppage
SW5
Power supply option to the
6
communication circuit
Remote water-temperature
7
setting
Water-temperature control
8
option
9 Individual/Multiple system
10 Display mode switch 7
1 Remote reset
Auto restart after power
2
failure
3 Water-temperature control
SW6
Pump-thermistor interlock
4
setting
5 Display mode switch 1
6 Display mode switch 2
7 Display mode switch 3
8 Display mode switch 4
9 Display mode switch 5
10 Display mode switch 6
"-" in the table indicates that the function in the corresponding row will be disabled regardless of the actual switch setting.
The factory setting for these items is OFF.
Refer to page 27 for how to reset errors.
Usage
Turns on and off the remote display during
scheduled operation.
Selects what the operation restoration
condition will be based on after the unit
was forced to stop based on the external
thermistor reading (water outlet
temperature).
Switches between supplying or not
supplying power to the communication
circuit.
Allows or disallows the water temperature
to be set using analog signals from a
remote location.
Selects either the external water
temperature sensor or the built-in sensor
to be used to control water temperature.
Selects between individual and Multiple
system
This switch is used in combination with dip
switches SW6-5 through 6-10 and push
switches SWP 1, 2, and 3 to configure or
view the settings when performing a test
run or changing the system configuration.
Enables or disables the error to be reset
from a remote location.
Enables or disables the automatic
restoration of operation after power failure
(in the same mode as the unit was in
before a power failure).
Switches between inlet-water-
temperature-based control and outlet-
water-temperature-based control.
Interlocks or does not interlock the
operation of the pump with the external
thermistor.
(Effective only when SW5-8 is set to ON.)
These switches are used in combination
with dip switches SW5-5 and push
switches SWP 1, 2, and 3 to configure or
view the settings when performing a test
run or changing the system configuration.
Factory setting
Circuit board
OFF setting
Depends on the unit Leave the setting as it is.
OFF
Leave the setting as it is.
Starts the pump when both
the outside and water
OFF
temperatures drop to
prevent water pipe freeze
up.
Leaves the operation
display on during the period
OFF
in which the unit is
scheduled to be stopped.
OFF
Leave the setting as it is.
OFF
Leave the setting as it is.
OFF
External thermistor
Does not supply power to
-
the communication circuit.
Disallows the water
OFF
temperature to be set using
external analog signals.
OFF
Built-in sensor on the unit
OFF
Individual system
OFF
Changes the 7-segment LED display mode.
Disables the error to be
ON
reset from a remote
location.
An alarm will be issued
when power is restored
after a power outage.
ON
The alarm will be reset
when the power is turned off
and then turned back on.
Outlet-water-temperature-
OFF
based control
The pump turns on when
the operation switch is
OFF
turned on regardless of the
Thermo-ON/Thermo-OFF
status.
OFF
Changes the 7-segment LED display mode.
OFF
Changes the 7-segment LED display mode.
OFF
Changes the 7-segment LED display mode.
OFF
Changes the 7-segment LED display mode.
OFF
Changes the 7-segment LED display mode.
OFF
Changes the 7-segment LED display mode.
19
Setting
ON setting
timing
At a reset
At a reset
Same as when set to OFF
At a reset
Turns off the operation
display during the period in
At a reset
which the unit is scheduled
to be stopped.
At a reset
At a reset
Built-in thermistor
At a reset
Supplies power to the
Any time
communication circuit.
Allows the water
temperature to be set using
At a reset
external analog signals.
External water temperature
At a reset
sensor
Multiple system
At a reset
Any time
Enables the error to be
reset from a remote
At a reset
location.
Automatically restores
operation after power
At a reset
failure.
Inlet-water-temperature-
At a reset
based control
Interlocks the operation of
the pump with the Thermo-
At a reset
ON/Thermo-OFF status.
Any time
Any time
Any time
Any time
Any time
Any time

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cahv-r450ya-hpb-bs

Table of Contents