When installed vertically (up flow), the pump must be
disabled firstly. Follow the 3.7.1 steps to disable the pump.
For the unit with external pump (9K ,12K &18K models),
the whole pump assembly can be removed. Then take the
cap on drain connector off and connect the drainpipe to
drain connector .
4. Outdoor unit installation(Side
Discharge Unit)
4.1
Service space for outdoor unit
4.2
Bolt pitch
Connector
Capacity(kBtu/h)
Connector
48/60
4.3
Install Outdoor Unit
Fix the outdoor unit with anchor bolts(M10)
Connector
Cation
Since the gravity center of the unit is not at its physical
center, so please be careful when lifting it with a sling.
Never hold the inlet of the outdoor unit to prevent it from
deforming.
Do not touch the fan with hands or other objects.
Do not lean it more than 45, and do not lay it sidelong.
Make concrete foundation according to the specifications
of the outdoor units.
Fasten the feet of this unit with bolts firmly to prevent it
from collapsing in case of earthquake or strong wind.
A
18
487
24
540
36
673
590
B
D
298
300
350
363
403
410
378
350
Page 82