6-10. FILTER PUMP & MOTOR
(Continued)
Dec. 2018
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
Removal:
1. Remove the bottom, rear panel and the right side panel.
2. Using a 5/8" wrench, loosen the front, flexible line fitting, on
the pump.
3. Using a 1" wrench, loosen the rear pump fitting.
4. Locate the appropriate conduit on the right side of the unti and
disconnect the conduit from the fryer.
5. Using a 1/2 in. wrench, remove the 4 bolts securing the motor
to the motor bracket and pull the pump and motor assembly
from fryer.
The following procedure only applies to units
manufactured prior to September 2018. For units
manufactured after September 2018, entire pump
assembly must be replaced. Follow procedure according
to manufacture date, otherwise property damage may
occur.
To replace pump on motor:
1. Using a 1/2 in. wrench, remove the 2 bolts securing the pump
to the motor and pull the pump from the motor.
2. Install a new seal kit (part no. 17476) onto shaft of motor.
3. Allign the shaft of the motor with the rotor on the inside of the
pump and push pump onto shaft of motor.
4. Secure the pump onto the motor with the 2 bolts.