1-4. ERROR CODES
DISPLAY
CAUSE
"E-4"
Control board
overheating
"E-5"
Oil overheating
"E-6 A"
Temperature probe
open
"E-6 B"
Temperature probe
shorted
"E-10 A"
High limit tripped
above 300 F
"E-10 B"
High limit tripped
below 300 F
"E-10 C"
High limit tripped
while cooking
"E-10 D"
High limit tripped
<5 min of Auto
Filter
"E-10 F"
High limit tripped
during filter cycle
"E-10 M"
High limit tripped
during melt mode
"E-10 Y"
High limit tripped
<5 min of "YES"
Dec. 2018
In the event of a control system failure, the digital display shows
an error message. The message codes are shown in the DISPLAY
column below. A constant tone is heard when an error code is
displayed, and to silence this tone, press any button.
CORRECTION
Turn switch to OFF position, then turn switch back to ON;
if display shows "E-4", the control board is getting too
hot; check the louvers on each side of the unit for obstruc-
tions
Turn switch to OFF position, then turn switch back to ON;
if display shows "E-5", the heating circuits and tempera-
ture probe should be checked
Turn switch to OFF position, then turn switch back to
ON; probe open if display shows "E-6A", the temperature
probe should be checked
Turn switch to OFF position, then turn switch back to ON;
if display shows "E-6B", the temperature probe should be
checked
Press the red reset button under the right side of the
controls; if high limit does not reset, high limit must be
replaced