6-7. TEMPERATURE PROBE
REPLACEMENT
(Continued)
May 2012
Replacement:
1. Pull-out on the drain valve knob and drain the oil from the vat.
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
2. Using a 3/8" socket, remove the 2 screws securing the burner
jet bracket and remove bracket.
3. Pull both burner jets from unit.
4. Using a 1/2" wrench, remove the nut on the compression fitting,
and remove the temperature probe from the vat.
5. Using a terminal extractor, remove the probe terminals from the
connector and pull remove probe from unit.
6-7
Model EEG-153, 154