6-5. HIGH TEMPERATURE
LIMIT CONTROL
(Continued)
May 2012
Replacement
If the tube is broken or cracked, the control opens, shutting off
electrical power. The control cannot be reset.
1. Pull-out on the drain valve knob and drain the oil from the vat.
2. Remove electrical power supplied to the fryer.
To avoid electrical shock or property damage, move the
power switch to OFF and disconnect main circuit
breaker, or unplug cord at wall receptacle.
3. Using a 3/8" socket, remove the 2 screws securing the burner
jet bracket and remove bracket.
4. Pull both burner jets from unit.
5. Using a 5/16" wrench, loosen small inside screw nut on
capillary tube.
6. Using a Phillip's-head screwdriver, remove the 2 screws the
capillary bulb bracket and pull bracket from unit.
7. Using an 11/16" crows-foot remove the large high limit fitting
in vat wall, and pull the high limit from inside the control area.
6-4
Model EEG-153, 154