ABB TPL65VA10 Operation Manual page 58

Table of Contents

Advertisement

5.2.2
If provided
NOTICE
© Copyright 2016 ABB. All rights reserved.
Maintenance
Cleaning the filter silencer
Filter silencer and connecting rod
81265
Filter ring (if provided)
81269
Connecting rods
81266
Cover grid
81272
Screwdriver
E
Insert unit = absorption segment + sheet­metal covering
Removing and cleaning filter silencer
Remove filter strip (81265).
Rinse filter strip (81265) using water with detergent additive or, if very
dirty, soak it and squeeze out carefully. Rinse it in cold water. Avoid
rough treatment (not a jet of water).
How dirty the filter strip (81265) is, depends on how clean the drawn-in
air is. Clean filter strip every 500 hours of service or more frequently if
necessary.
Operation Manual / TPL65VA10 / VA30
5
5.2
81136
Absorption segment
81137
Sheet-metal covering
81135
Filter silencer body
81273
Lock nut