Practical Guide To Installation; Specifications; Product Service - Panasonic WhisperRemodel RG-R811LA Installation Instructions Manual

Hide thumbs Also See for WhisperRemodel RG-R811LA:
Table of Contents

Advertisement

MAINTENANCE (CLEANING) (CONTINUED)
Maintenance of unit
1
NOTE: The grille should be dry after cleaning.
Clean grille. (Don't put into water. Use non-abrasive kitchen detergent, wipe dry with clean cloth).
1
2
Remove dust and dirt from fan body using a vacuum cleaner.
3
Using a cloth dampened with kitchen detergent, remove any dirt from fan body. Wipe dry with a clean
cloth. Reinstall grille after finishing.

PRACTICAL GUIDE TO INSTALLATION

Properly insulate the area around the fan to minimize
building heat loss and gain. Loose fill or batt insulation
can be placed directly over the fan housing in the
attic. Panasonic fans do not create excessive heat
which is a common problem with recessed light
fixtures and some competitor's fan/light combination.
Our efficient, cool-running motors do not create
enough ambient heat to be subjected to these
limitations. The ducting from this fan to the outside of
the building has a strong effect on the air flow, noise
and energy use of the fan. Use the shortest, straightest
duct routing possible for best performance, and avoid
installing the fan with smaller ducts than recommended.
Insulation around the ducts can reduce energy loss
and inhibit mold growth. Fans installed with existing ducts may not achieve their rated air flow.

SPECIFICATIONS

Air
Model No.
direction
RG-R811LA
Exhaust

PRODUCT SERVICE

Warning Concerning Removal of Covers. The unit should be serviced by qualified technicians only. Your product
is designed and manufactured to ensure a minimum of maintenance. Should your unit require service or parts,
call Panasonic Call Center at 1-866-292-7299 (USA).
Duct
Voltage
Frequency
diameter
(V)
(Hz)
(inches)
60
120
Drywall
Vacuum cleaner
2
4 inches or 3 inches roof jack, wall cap,
or soffit vent with backdraft damper
Mechanically connect duct to termination
and seal with mastic or approved foil
faced tape
2-3 ft straight run before elbow
In attic installation,
caulk box to drywall
Short piece of flexible duct helps
alignment and absorbs sound.
Clamps plus mastic or approved
foil faced tape at all flex joints
Air volume
Noise
at 0.1" WG
(sones)
(CFM)
80
4
110
Foil tape tightly covers all metal
duct joints (glue PVC joints)
Speed
(rpm)
905
0.4
1.1
1043
Drywall
Gloves
3
Insulation
Weight
Power
(W)
lb. (k )
7.1
9.9(4.5)
11.6
11