Table 28. Event descriptions and recommended actions (continued)
Number
Severity
95
Error
96
Info.
103
Info.
104
Info.
105
Info.
106
Info.
107
Error
108
Info.
109
Info.
110
Info.
111
Info.
Description/Recommended actions
Both controllers in an Active-Active configuration have the same serial number. Non-unique
serial numbers can cause system problems. For example, WWNs are determined by serial
number.
Recommended actions:
● Remove one of the controller modules and insert a replacement, then return the removed
module to be reprogrammed.
Pending configuration changes that take effect at startup were ignored because customer data
might be present in cache.
Recommended actions:
● If the requested configuration changes did not occur, make the changes again and then use a
user-interface command to shut down the Storage Controller and then restart it.
The name has been changed for the indicated volume.
Recommended actions:
● No action is required.
The size has been changed for the indicated volume.
Recommended actions:
● No action is required.
The default LUN (logical unit number) has been changed for the indicated volume.
Recommended actions:
● No action is required.
The indicated volume has been added to the indicated pool.
Recommended actions:
● No action is required.
A serious error has been detected by the controller. In a single-controller configuration, the
controller will restart automatically. In an Active-Active configuration, the partner controller will
kill the controller that experienced the error.
Recommended actions:
● Download the debug logs from your storage system and contact technical support. A service
technician can use the debug logs to determine the problem.
The indicated volume has been deleted from the indicated pool.
Recommended actions:
● No action is required.
The statistics for the indicated volume have been reset.
Recommended actions:
● No action is required.
Ownership of the indicated disk group has been given to the other controller.
Recommended actions:
● No action is required.
The link for the indicated host port is up.
This event indicates that a problem reported by event 112 is resolved. For a system with FC
ports, this event also appears after loop initialization
Recommended actions:
● No action is required.