Download Print this page
Trotec BE 38 Operating Manual

Trotec BE 38 Operating Manual

Clamp meter
Hide thumbs Also See for BE 38:

Advertisement

Quick Links

BE 38
EN
OPERATING MANUAL
CLAMP METER

Advertisement

loading

Summary of Contents for Trotec BE 38

  • Page 1 BE 38 OPERATING MANUAL CLAMP METER...
  • Page 2: Table Of Contents

    • Do not swallow batteries! If a battery is swallowed, it can cause severe internal burns within 2 hours! These burns can lead to death! BE38 • If you think batteries might have been swallowed or otherwise entered the body, seek medical attention immediately! https://hub.trotec.com/?id=40557 clamp meter BE 38...
  • Page 3 Work on the electrical components must only be carried out by an authorised specialist company! To use the device for its intended use, only use accessories and spare parts which have been approved by Trotec. Warning Risk of suffocation! Foreseeable misuse Do not leave the packaging lying around.
  • Page 4: Information About The Device

    Connection for measuring cable (red) continuity testing Connection for measuring cable (black) Measuring DC voltage of up to bis 300 V Display Measuring AC voltage of up to bis 300 V Lever for opening the clamp Measuring alternating current of up to 400 A clamp meter BE 38...
  • Page 5: Transport And Storage

    Resistance 2000 Ω 1 Ω ± (1.2 % + 2 The figure 1 will digits) be indicated on the display. 200 kΩ 100 Ω ± (1.5 % + 2 The figure 1 will digits) be indicated on the display. clamp meter BE 38...
  • Page 6: Operation

    In this case, the display shows either no measured values or they are incorrect. Wait a few minutes until the device has become adjusted to the changed conditions before carrying out a measurement. clamp meter BE 38...
  • Page 7 ð The component's forward voltage will be displayed (approx. 0.2 V to 0.3 V for Ge diodes and approx. 0.5 V to 0.8 V for Si diodes). clamp meter BE 38...
  • Page 8 • When holding onto the clamp meter, make sure not to ð The measured value will be displayed in the reach behind the protection against contact (4): measurement value display (13). • When performing measurements, align the conductor to be tested in the centre of the clamp. clamp meter BE 38...
  • Page 9: Maintenance And Repair

    According to Waste Electrical and Electronic Equipment Regulations 2013 (SI 2013/3113) (as amended) and the Waste Batteries and Accumulators Regulations 2009 (SI 2009/890) (as amended), devices that are no longer usable must be collected separately and disposed of in an environmentally friendly manner. clamp meter BE 38...
  • Page 10 Trotec GmbH Grebbener Str. 7 D-52525 Heinsberg +49 2452 962-400 +49 2452 962-200 info@trotec.com www.trotec.com...

This manual is also suitable for:

3510205239