    • Do not remove any safety signs, stickers or labels from the device. Keep all safety signs, stickers and labels in legible condition. • Do not open the device with a tool. • Observe the storage and operating conditions as given in the Technical data chapter. clamp meter BE44...
  • Page 3: Information About The Device

    To use the device for its intended use, only use accessories and If you are unsure, select the largest measuring range. spare parts which have been approved by Trotec. Unplug the cable before changing the measuring range. Improper use...
  • Page 4 Rotary switch Setting buttons Display Input connection for measuring cable (red) COM connection for measuring cable (black) Lamp ON/OFF button Lever for opening the clamp NCV sensor Test probes Protection against contact Red measuring cable Black measuring cable clamp meter BE44...
  • Page 5 For measuring frequency or duty cycle 35 NCV measurement Activates the NCV measurement (for the non-contact detection of alternating voltages). 36 AC / DC voltage Activates the measurement of AC or DC voltages. 37 Frequency / duty For measuring frequency or duty cycle cycle clamp meter BE44...
  • Page 6 99.99 kHz 10 Hz • 1 x Red measuring cable 999.9 kHz 100 Hz • 1 x Black measuring cable 9.999 MHz 1 kHz Not specified • 1 x Label with safety information • 3 x 1.5 V battery AAA • 1 x Manual clamp meter BE44...
  • Page 7: Transport And Storage

    1. Loosen the screw and open the cover of the battery 2. Turn the rotary switch (3) to position 36. compartment. ð The direct current icon is displayed in the direct current 2. Insert the batteries into the battery compartment with indication (28) on the display. correct polarity. clamp meter BE44...
  • Page 8 Warning of electrical voltage Risk of electric shock and risk of injury! • For current measurements align the conductor to be tested in the centre of the clamp. • When performing non-contact measurements, disconnect the measuring cables from the device. clamp meter BE44...
  • Page 9 Make sure that the power of the electric circuit is switched off and all capacitors are completely discharged. • When holding onto the measuring cables, make sure not to reach behind the protection against contact (12). clamp meter BE44...
  • Page 10 4. Connect the test probes (11) of the measuring cables to the object to be measured. ð The measured value will be displayed in the measurement value display (24). 5. Press the function button twice to reset the measurement value display (24). clamp meter BE44...
  • Page 11: Maintenance And Repair

    3. Carry out another measurement. or device testing, contact the manufacturer. ð The difference between the current measurement and the reference value is now indicated on the measurement value display (24). 4. Press the compare button (32) to exit compare mode. clamp meter BE44...
  • Page 12: Errors And Faults

    Directive 2006/66/EC of the European Parliament and of the Council of 6 September 2006 on batteries and accumulators. Please dispose of batteries and accumulators according to the relevant legal requirements. clamp meter BE44...