Outdoor Unit Fan Motor - Fujitsu GENERAL ASHG18KMTE Service Manual

Hide thumbs Also See for GENERAL ASHG18KMTE:
Table of Contents

Advertisement

4-5. Outdoor unit fan motor

Check point 1. Check rotation of fan
Rotate the fan by hand when operation is off.
(Check if fan is caught, dropped off or locked motor)
If fan or bearing is abnormal, replace it.
Check point 2. Check resistance of outdoor fan motor
Refer to below. Circuit-test "Vm" and "GND" terminal
NOTE: Vm: DC voltage, GND: Earth terminal
If they are short-circuited (below 300 kΩ), replace outdoor fan motor and main PCB.
FM
4-5. Outdoor unit fan motor
1 (Red)
2
Red
1
3
Black
4
5
White
6
Yellow
4 (Black)
7
Brown
5 (→hite)
6 (Yellow)
7 (Brown)
- (03-54) -
Terminal function
Pin number
(wire color)
DC voltage (Vm)
No function
No function
Earth terminal (GND)
Control voltage (Vcc)
Speed command (Vsp)
Feed back (FG)
(symbol)
4. Service parts information

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

General ashg24kmteGeneral aohg18kmtaGeneral aohg24kmta

Table of Contents