Details Of Control Input Function - Fujitsu GENERAL ASHG18KMTE Service Manual

Hide thumbs Also See for GENERAL ASHG18KMTE:
Table of Contents

Advertisement

2-4. Details of control input function

¢ Operation/Stop mode 1
• In the case of "Edge" input
External input and
Function
setting
Rotary
switch
46-00
• In the case of "Pulse" input
External input and
Function
setting
Rotary
switch
46-00
Indoor unit operation
Remote controller
NOTES:
• The last command has priority.
• The indoor units within the same remote controller group operates in the same mode.
2-4. Details of control input function
output PCB
SW302
Input of indoor unit
External input and
1
Edge
output PCB
On
CN313
Off
On
Indoor unit operation
Off
Remote controller
output PCB
SW302
External input and
1
Pulse
output PCB
On
CN313
Off
On
CN314
Off
On
Off
External input
CN46
CN313
On
External input
CN313
CN314
- (05-15) -
Input signal
Command
Off
On
Operation
On
Off
Stop
Off
On
Operation
On
Off
Stop
Input signal
Command
Operation
Pulse
Stop
On
2. External input and output

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

General ashg24kmteGeneral aohg18kmtaGeneral aohg24kmta

Table of Contents