Page 2
• Product specifications and design are subject to change without notice for future improvement. • For further details, please check with our authorized dealer. Trademarks ™ FGLair is trademark of Fujitsu General Limited in the United States, other countries or both. ™ Google Play is trademark of Google Inc. ®...
1. Specifications Wall mounted Type Inverter heat pump Model name ASHG07KMCC ASHG09KMCC ASHG12KMCC ASHG14KMCC Power supply 230 V ~ 50 Hz Available voltage range 198—264 V 2.00 2.50 3.40 4.20 Rated Btu/h 6,800 8,500 11,600 14,300 Cooling 0.9—3.0 0.9—3.2 0.9—3.9 0.9—4.4 Min.—Max.
Page 7
Specifications for Lot10 Model name ASHG07KMCC ASHG09KMCC ASHG12KMCC ASHG14KMCC Cooling Energy efficiency class Heating (Average) Cooling 2.0 (35 °C) 2.5 (35 °C) 3.4 (35 °C) 4.2 (35 °C) Pdesign Heating (Average) 2.3 (-10 °C) 2.4 (-10 °C) 2.5 (-10 °C) 4.0 (-10 °C) SEER Cooling...
2. Dimensions 2-1. Models: ASHG07KMCC, ASHG09KMCC, ASHG12KMCC, and ASHG14KMCC Unit: mm (834) Outline of indoor unit for pipe inlet Ø65 for pipe inlet Ø65 - 4 - 2-1. Models: ASHG07KMCC, ASHG09KMCC, ASHG12KMCC, and ASHG14KMCC 2. Dimensions...
Page 9
¢ Installation space requirement Provide sufficient installation space for product safety. Unit: mm 70 or more 40 or more Wall hook bracket Outline of the indoor unit 107 or more 183 or more 1,500 or more The flare connection part should be installed outdoors.
4. Capacity table Capacity tables show each of following values calculated based on the outdoor temperature and the indoor temperature, under given Airflow Rate (AFR): For cooling capacity: Total Capacity (TC), Sensible Heat Capacity (SHC), and Input Power (IP) For heating capacity: Total Capacity (TC) and Input Power (IP) 4-1.
5. Fan performance 5-1. Air velocity distributions ¢ Models: ASHG07KMCC, ASHG09KMCC, and ASHG12KMCC Fan speed Operation mode Measuring conditions HIGH Unit: m/s Top view Vertical airflow direction louver: Up Horizontal airflow direction louver: Center Unit: m/s Top view Vertical airflow direction louver: Up Horizontal airflow direction louver: Left &...
Page 15
¢ Model: ASHG14KMCC Fan speed Operation mode Measuring conditions HIGH Unit: m/s Top view Vertical airflow direction louver: Up Horizontal airflow direction louver: Center Unit: m/s Top view Vertical airflow direction louver: Up Horizontal airflow direction louver: Left & Right Unit: m/s Side view Vertical airflow direction louver: Up...
6-2. Sound level check point Microphone Microphone NOTE: Detailed shape of the actual indoor unit might be slightly different from the one illustrated above. - 18 - 6-2. Sound level check point 6. Operation noise (sound pressure)
7. Safety devices Model Type of Protection form protection ASHG07KMCC ASHG09KMCC ASHG12KMCC Circuit Current fuse (PCB*) 250 V, 3.15 A protection °C Activate Fan motor stop Fan motor Thermal protection protection °C Reset Fan motor restart Model Type of Protection form protection ASHG14KMCC Circuit...
8. External input and output With using external input and output functions, this product can be operated inter-connectedly with an external device. Connector Input Output Remarks CNA01 Control input — See external input/output CNB01 — Operation status output settings for details. CNB02 —...
Page 25
• Circuit diagram example • Contact capacity: DC 24 V or more, Indoor unit 10 mA or more. Communication kit Connected unit control PCB • *: Make the distance from the PCB to Example: Switch Connector the connected unit within 10 m. •...
Page 26
• Optional part Part name Model name Exterior External input wire External connect kit UTY-XWZXZ5 Communication kit UTY-TWBXF2 * For operating the external function, the wall mounted type requires the communication kit in addi- tion to the wire (UTY-XWZXZ5). - 22 - 8-1.
8-2. External output With using external output function, operating status of this product can be transmitted to the exter- nal device, and also, this product can be inter-connected with the external device. ¢ Operation status output Air conditioner operation status signal can be output. •...
Page 28
¢ Error status output Air conditioner error status signal can be output. • Circuit diagram example: Indoor unit control PCB Communication kit Connected unit Connector DC 24 V Example: Relay unit Example: Display Relay power supply 10 m* Signal Optional parts Locally purchased –...
9. Group connection Wiring regulation on the remote controllers in the multi split models are reviewed and allowed for group connection. Example of group connection Indoor unit Indoor unit Outdoor unit Outdoor unit *Exterior of each device shown above might be different from the actual one. NOTES: •...
• Required parts for group connection – Optional part: Indoor unit type Communication kit UTY-TWBXF Wall mounted UTY-XWZXZ5 UTY-TWBXF2 As for the optional parts, refer to Chapter 13-2. "Others" on page 37. – Service part: Wire with connector (Service part no. 9705932012) Wiring example for multiple remote control or group control: Crimping terminal and its insulation cap (Locally purchased)
11. Function settings To adjust the functions of this product according to the installation environment, various types of function settings are available. NOTE: Incorrect settings can cause a product malfunction. 11-1. Function settings by using remote controller Some function settings can be changed on the remote controller. After confirming the setting proce- dure and the content of each function setting, select appropriate functions for your installation envi- ronment.
Page 34
NOTES: • The air conditioner custom code is set to prior to shipment. • The remote controller resets to custom code when the batteries on the remote controller are replaced. If you use a custom code other than code , reset the custom code after replacing the batteries.
Page 35
¢ Contents of function setting Each function setting listed in this section is adjustable in accordance with the installation environ- ment. NOTE: Setting will not be changed if invalid numbers or setting values are selected. Function setting list Function no. Functions Remote controller address setting Filter sign...
Page 36
2) Filter sign Select appropriate intervals for displaying the filter sign on the indoor unit according to the estimated amount of dust in the air of the room. If the indication is not required, select "No indication" (03). Function number Setting value Setting description Factory setting...
Page 37
4) Room temperature control for wired remote controller sensor Depending on the installed environment, correction of the wire remote temperature sensor may be required. Select the appropriate control setting according to the installed environment. To change this setting, set Function 42 to Both “01”. Ensure that the Thermo Sensor icon is displayed on the remote controller screen.
Page 38
7) Remote controller custom code (Only for wireless remote controller) The indoor unit custom code can be changed. Select the appropriate custom code. Function number Setting value Setting description Factory setting ♦ 8) External input control "Operation/Stop" mode or "Forced stop" mode can be selected. Function number Setting value Setting description...
11-2. Custom code setting for wireless remote controller To interconnect the air conditioner and the wireless remote controller, assignment of the custom code for the wireless remote controller is required. NOTE: Air conditioner cannot receive a signal if the air conditioner has not been set for the custom code.
13. Optional parts 13-1. Controllers Exterior Part name Model name Summary Large and full-dot liquid crystal screen, wide and large keys easy to press, user-intuitive arrow key. Wired remote Wire type: Polar 3-wire UTY-RVNGM controller Optional communication kit is necessary for installation. Room temperature can be controlled by detecting the temperature accurately with built-in thermo sensor.
1. Specifications Type Inverter heat pump Model name AOHG07KMCC AOHG09KMCC AOHG12KMCC AOHG14KMCC Power supply 230 V ~ 50 Hz Available voltage range 198—264 V Starting current Cooling 1,650 1,650 1,700 1,680 Airflow rate Heating 1,450 1,450 1,470 1,580 Type × Q'ty Propeller fan ×...
2. Dimensions 2-1. Models: AOHG07KMCC, AOHG09KMCC, and AOHG12KMCC Unit: mm 4-M10 hole Pitch of bolts for installation Top view Side view Front view Side view Airflow Drain port Ø42 Bottom view Side view (Valve part) - 41 - 2-1. Models: AOHG07KMCC, AOHG09KMCC, and AOHG12KMCC 2.
2-2. Model: AOHG14KMCC Unit: mm 4-M10 hole Pitch of bolts for installation Top view Side view Front view Side view Airflow Drain port Ø42 Bottom view Side view (Valve part) - 42 - 2-2. Model: AOHG14KMCC 2. Dimensions...
3. Installation space 3-1. Models: AOHG07KMCC, AOHG09KMCC, AOHG12KMCC, and AOHG14KMCC ¢ Space requirement Provide sufficient installation space for product safety. CAUTION Keep the space shown in the installation examples. If the installation is not performed accordingly, it could cause a short circuit and result in a lack of operating performance.
Page 48
Multiple outdoor unit installation • Provide at least 250 mm of space between the outdoor units if multiple units are installed. • When routing the piping from the side of an outdoor unit, provide space for piping. • No more than 3 units must be installed side by side. When 3 units or more are arranged in a line, provide the space as shown in the following ex- ample “When an obstruction in the upper space:”.
Page 49
Outdoor units installation in multi-row Unit: mm Single parallel unit arrangement Multiple parallel unit arrangement 100 or more 200 or more 1,000 or more 2,000 or more 200 or more 400 or more 500 or more 1,000 or more 200 or more 250 or more 1,000 or more...
6. Capacity compensation rate for pipe length and height difference Height difference H Indoor unit is higher than outdoor unit Indoor unit is lower than outdoor unit Outdoor unit Indoor unit Outdoor unit Indoor unit Connection pipe Connection pipe 6-1. Models: AOHG07KMCC and AOHG09KMCC NOTE: Values mentioned in the table are calculated based on the maximum capacity.
6-2. Model: AOHG12KMCC NOTE: Values mentioned in the table are calculated based on the maximum capacity. Pipe length (m) COOLING — — — 0.858 0.868 — — 0.929 0.872 0.882 Indoor unit is higher than outdoor unit *1 — 0.960 0.933 0.876 0.885...
9-2. Sound level check point Rear Microphone Microphone Airflow Side view Rear view NOTE: Detailed shape of the actual outdoor unit might be slightly different from the one illustrated above. - 56 - 9-2. Sound level check point 9. Operation noise (sound pressure)
10. Electrical characteristics Model name AOHG07KMCC AOHG09KMCC AOHG12KMCC AOHG14KMCC Voltage 230 ~ Power supply Frequency Max operating current *1 Starting current Circuit breaker current Power cable Cross- Wiring sectional spec. *2 area Connection cable *3 Limited wiring length *1: Maximum operating current is the total current of the indoor unit and the outdoor unit. *2: Selected sample based on Japan Electrotechnical Standards and Codes Committee E0005.
11. Safety devices Model Type of Protection form protection AOHG07KMCC AOHG09KMCC 250 V, 20 A Circuit protection Current fuse (Main PCB) 250 V, 5 A 100±15 °C Activate Fan motor stop Fan motor Thermal protection protection 95±10 °C Reset Fan motor restart 110 °C Activate Terminal protection...