Fujitsu ASHG07KPCA Service Manual

Fujitsu ASHG07KPCA Service Manual

Wall-mounted type, refrigerant r32, indoor/outdoor unit

Advertisement

Split type room air conditioner
Wall-mounted type
Indoor unit
ASHG07KPCA
ASHG09KPCA
ASHG12KPCA
C ON T E NT S
SPECIFICATIONS. . . . . . . . . . . . . . . . . . .
DIMENSIONS . . . . . . . . . . . . . . . . . . . . . .
REFRIGERANT SYSTEM DIAGRAM. . . .
PCB CIRCUIT DIAGRAM . . . . . . . . . . . . .
ERROR DETECTION . . . . . . . . . . . . . . . .
ACCESSORIES . . . . . . . . . . . . . . . . . . .
Outdoor unit
AOHG07KPCA
AOHG09KPCA
AOHG12KPCA
1
4
7
8
10
14

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu ASHG07KPCA

  • Page 1 Split type room air conditioner Wall-mounted type Indoor unit Outdoor unit ASHG07KPCA AOHG07KPCA ASHG09KPCA AOHG09KPCA ASHG12KPCA AOHG12KPCA C ON T E NT S SPECIFICATIONS....
  • Page 2: Specifications

    Specifications Wall mounted Type Inverter heat pump Model name ASHG07KPCA ASHG09KPCA ASHG12KPCA Power supply 230 V ~ 50 Hz Power supply intake Outdoor unit Available voltage range 198—264 V 2.00 2.50 3.40 Rated Btu/h 6,800 8,500 11,600 Cooling 0.9—2.8 0.9—3.0 0.9—3.7...
  • Page 3 Specifications for Lot10 Model name ASHG07KPCA ASHG09KPCA ASHG12KPCA Cooling Energy efficiency class Heating (Average) Cooling 2.0 (35 °C) 2.5 (35 °C) 3.4 (35 °C) P design Heating (Average) 2.2 (-10 °C) 2.4 (-10 °C) 2.5 (-10 °C) SEER Cooling kWh/kWh...
  • Page 4 Type Inverter heat pump Model name AOHG07KPCA AOHG09KPCA AOHG12KPCA Power supply 230 V ~ 50 Hz Power supply intake Outdoor unit Available voltage range 198—264 V Starting current Cooling 1,650 1,650 1,700 Airflow rate Heating 1,450 1,450 1,470 Type × Q'ty Propeller fan ×...
  • Page 5: Dimensions

    Dimensions Models: ASHG07KPCA, ASHG09KPCA, and ASHG12KPCA Unit: mm Outline of indoor unit for pipe inlet Ø65 for pipe inlet Ø65 - 4 -...
  • Page 6  Installation space requirement Provide sufficient installation space for product safety. Unit: mm 30 or more 40 or more Wall hook bracket Outline of the indoor unit 107 or more 163 or more 1,500 or more The flare connection part should be installed outdoors.
  • Page 7 Models: AOHG07KPCA, AOHG09KPCA, and AOHG12KPCA Unit: mm 4-M10 hole Pitch of bolts for installation Top view Side view Front view Side view Airflow Drain port Ø42 ) t r - 6 -...
  • Page 8 Refrigerant circuit Heat exchanger 3-way (INDOOR) valve 2-way Muffler valve 4-way valve Strainer Expansion valve Heat exchanger Strainer (OUTDOOR) Cooling Heating : Thermistor (Discharge temperature) : Thermistor (Outdoor temperature) : Thermistor (Heat exchanger out temperature) : Thermistor (Room temperature) : Thermistor (Pipe temperature) - 7 -...
  • Page 9: Pcb Circuit Diagram

    PCB circuit diagram Models : ASHG07KPCA ASHG09KPCA ASHG12KPCA CONTROL UNIT ASHG07KPCA : EZ-0180BHSE ASHG09KPCA : EZ-0180CHSE ASHG12KPCA : EZ-0180DHSE CN5 DC Fan motor CN1 Thermistor Characteristics. Terminal Lead wire Function of terminal Temperature Pin No. code color ( 20 ( 30...
  • Page 10 Models : AOHG07KPCA AOHG09KPCA AOHG12KPCA INVERTER ASSEMBLY AOHG07KPCA : EZ-018GHUE AOHG09KPCA : EZ-018HHUE AOHG12KPCA : EZ-018KHUE EMI FILTER F8CT TR-28-16-13 3 TURNS REACTOR COMPRESSOR UL3271 AWG16 13mH 8A W400 DC Resistance 408.0m Compressor UL3271 AWG16 W401 Winding Resistance WHITE WHITE EMI FILTER EMI FILTER UL3271 AWG16...
  • Page 11: Error Detection

    Error detection If you use a wireless remote controller, the lamp on the photo detector unit will output error codes by way of blinking patterns. If you use a wired remote controller, error codes will ap- pear on the remote control display. See the lamp blinking patterns and error codes in the table.
  • Page 12 Error display OPERATION TIMER ECONOMY Error code Description lamp lamp lamp (green) (orange) (green) Serial communication error   • Wired remote controller com- munication error   • Server room control communi- cation error Check run unfinished   Automatic airflow adjustment error External communication error ...
  • Page 13 Error display OPERATION TIMER ECONOMY Error code Description lamp lamp lamp (green) (orange) (green) Indoor unit heat ex. middle temp.   sensor error Indoor unit fan motor error   Indoor unit error   (15) Outdoor unit main PCB ...
  • Page 14 Error display OPERATION TIMER ECONOMY Error code Description lamp lamp lamp (green) (orange) (green) • Sub-cool Heat Ex. gas inlet temp. sensor error   • Sub-cool Heat Ex. gas outlet temp. sensor error Liquid pipe temp. sensor error  ...
  • Page 15: Accessories

    Accessories Part name Exterior Q’ty Part name Exterior Q’ty Operating manual Battery Operating manual Cloth tape (CD-ROM) Installation manual Tapping screw Wall hook bracket Remote controller - 14 -...
  • Page 16 Part name Exterior Q’ty Part name Exterior Q’ty Drain pipe - 15 -...
  • Page 17 Optional parts Exterior Part name Model name Summary Remote Wall or pillar mountable, and holds the UTZ-RXLA controller holder wireless remote controller. Remotely manage an air conditioning Wireless LAN UTY-TFSXF2 system using mobile devices such as adapter smartphones and tablets. - 16 -...
  • Page 18 1902G4799...