Servicing - KNF UN012AT.16I Operating And Installation Instructions

Diaphragm vacuum pumps and compressors
Table of Contents

Advertisement

Diaphragm Vacuum Pumps UN012, UN024, UN036_I
Spare part
13
5.

Servicing

Before working on the pump, isolate the power supply
securely, then check that the lines are not live.
Danger of burning yourself when using hot media
Let the pump head cool down before working on
the pump
VORSICHT
Diaphragm and valve plates are the only parts of the pump subject
to wear. They are simple to change.
Always change diaphragm, valve plates and sealing rings at the
same time. If diaphragm and valve plates are not changed at the
same time the nominal performance of the pump is not guaranteed
after the service.
Health hazard due to dangerous substances in the
pump
Depending on the substances transferred, caustic
burns or poisoning are possible.
WARNUNG
Wear protective clothing if necessary, e.g.
protective gloves.
Clean pump with suitable measures.
After opening the pump head, or replacing the diaphragm and
valve plates the high gas-tightness is no longer guaranteed. A leak
test is able to verify that the original standard of gas-tightness has
been achieved.
Spare part*
Valve plates
Wave diaphragm
O-Rings
Tab. 1: Spare parts
.
Quantity
2 (per pump head)
1 (per pump head)
2 (per pump head)
* According to Spare parts list, chapter 8