Description

The ACL875FL-KP is a standalone digital keypad for access
control applications with backlit keys, 99 user codes, 2 outputs
and 1 push button input. Authorized users can be assigned
specific codes for use in access control applications, electrical
switching, and arming/disarming alarm systems. The users can
be assigned to activate the first, the second or both outputs.
There is a 30 seconds lockout after 8 successive invalid PIN
codes.
The tamper switch output can trigger the alarm system if an
attempt is made to open or remove the unit from the wall.

Mounting

Figure 1: Mounting instructions
© 2022 Carrier

Wiring

Figure 2: Wiring instructions
ACL875FL-KP
Backlight ON/OFF
Master code reset jumper

Application diagram

15 to 24 VAC
ACL875FL-KP
NO
COM
470 nF
10K / ½W
Note:
Strike can be connected to DC.
12 to 24 VDC
Diode
1N4001
COM
NC
1 / 4
Power upply
12/24V
(12-24V DC
AC/DC
15-24V AC)
GND
Push button
PB
Tamper
NO1
COM1
Relay 1
NC1
NO2
COM2
Relay 2
NC2
GND (PB)
PB
ACL875FL-KP
GND (PB)
PB
P/N 1073522-EN • REV B • ISS 06JUL22
s
,

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ACL875FL-KP and is the answer not in the manual?

Questions and answers

Summary of Contents for Aritech ACL875FL-KP

  • Page 1 ACL875FL-KP COM2 Relay 2 Description The ACL875FL-KP is a standalone digital keypad for access Backlight ON/OFF control applications with backlit keys, 99 user codes, 2 outputs and 1 push button input. Authorized users can be assigned Master code reset jumper specific codes for use in access control applications, electrical switching, and arming/disarming alarm systems.
  • Page 2 Authorize using the master code, or 000 when using the Tamper switch keypad for the first time. Validate the code by pressing B. If you are not authorized to enter the programing mode, the keypad transmits multiple short beeps, and the orange LED blinks rapidly.
  • Page 3 Output 2 outputs that operate in pulse (01 to 99 s), or latch mode (00) Contact information Input 1 pushbutton firesecurityproducts.com or www.aritech.com Tamper Yes, activated on frame removal Current Consumption Standby: 30 mA maximum: 100 mA IP Rating IP40 −25 to +50°C...
  • Page 4 P/N 1073522-EN • REV B • ISS 06JUL22 4 / 4...

Table of Contents