Malfunctions
An obstacle is not
detected
An obstacle is
detected incorrectly
Loading-LEDs (red
and blue) light up
simultaneously
TDIMC1_4_User Manual_IMC-1.1.0_EN
Possible reasons
Dirt on the sensors
Obstacle is out of the range of 0,3
and 4,0 meters
The material or shape of an object
can cause unfavourable ultrasonic
reflections, so that it is not
detected as an obstacle.
Ultrasonic sensors are covered by
clothing
Obstacle lies centrally between the
ultrasonic cones
At a larger measuring range, objects
located to the side of the selected
walking direction may be detected,
as the measuring range of the
ultrasonic sensors becomes wider
in a conical shape in the distance.
Hardware error
Necessary actions
Cleaning the InnoMake Clip see
section 6.2
Approach to or distance from an
obstacle in the walking direction
to bring it into the measuring
range and obtain appropriate
feedback
Pay attention to the proper
execution of the primary aid
during the application of
InnoMake Clip.
Do not wear clothing that
interferes with vibration feedback
or obstacle detection
Pay attention to the proper
execution of the primary aid
while using the InnoMake Clip
Limitation of the measuring range
of the InnoMake Clip to 1.5
meters in order to reduce the
width of the ultrasonic cones
Contact dealer