n Enkele buitenunit
Model met
Model voor
Nominale
warmtepomp
alleen koelen
spanning
MMY-
MMY-
(V-Ph-Hz)
MAP0501HT8 MAP0501T8
400-3-50
MAP0601HT8 MAP0601T8
400-3-50
MAP0801HT8 MAP0801T8
400-3-50
MAP1001HT8 MAP1001T8
400-3-50
MAP1201HT8 MAP1201T8
400-3-50
n Combinatie van buitenunits
Model met
Model voor
Nominale
warmtepomp
alleen koelen
spanning
MMY-
MMY-
(V-Ph-Hz)
AP1401HT8
AP1401T8
400-3-50
AP1601HT8
AP1601T8
400-3-50
AP1801HT8
AP1801T8
400-3-50
AP2001HT8
AP2001T8
400-3-50
AP2201HT8
AP2201T8
400-3-50
AP2211HT8
AP2211T8
400-3-50
AP2401HT8
AP2401T8
400-3-50
AP2411HT8
AP2411T8
400-3-50
AP2601HT8
AP2601T8
400-3-50
AP2801HT8
AP2801T8
400-3-50
AP3001HT8
AP3001T8
400-3-50
AP3201HT8
AP3201T8
400-3-50
AP3211HT8
AP3211T8
400-3-50
AP3401HT8
AP3401T8
400-3-50
AP3411HT8
AP3411T8
400-3-50
AP3601HT8
AP3601T8
400-3-50
AP3611HT8
AP3611T8
400-3-50
AP3801HT8
AP3801T8
400-3-50
AP4001HT8
AP4001T8
400-3-50
AP4201HT8
AP4201T8
400-3-50
AP4401HT8
AP4401T8
400-3-50
AP4601HT8
AP4601T8
400-3-50
AP4801HT8
AP4801T8
400-3-50
Legenda
MCA
: Minimum Circuit Amps (max. stroomsterkte circuit)
MOCP
: Max. stroomsterktebescherming (Amps)
ICF
: Maximum Instantaneous Current Flow Start (max. startstroom)
RLA
: Rated Load Amps (toeg. lasttstroomsterkte)
Spanningsbereik
Min
Max
RLA
LRA
342
457
4.0 + 4.0
342
457
4.6 + 4.6
342
457
5.2 + 5.2
342
457
6.5 + 6.5
342
457
9.5 + 9.5
Spanningsbereik
Unit nr.1
Min
Max
RLA
LRA
RLA
342
457
5.2 + 5.2
4.6 + 4.6
342
457
5.2 + 5.2
5.2 + 5.2
342
457
6.5 + 6.5
5.2 + 5.2
342
457
6.5 + 6.5
6.5 + 6.5
342
457
5.2 + 5.2
5.2 + 5.2
342
457
9.5 + 9.5
6.5 + 6.5
342
457
5.2 + 5.2
5.2 + 5.2
342
457
9.5 + 9.5
9.5 + 9.5
342
457
6.5 + 6.5
5.2 + 5.2
342
457
6.5 + 6.5
6.5 + 6.5
342
457
6.5 + 6.5
6.5 + 6.5
342
457
5.2 + 5.2
5.2 + 5.2
342
457
9.5 + 9.5
6.5 + 6.5
342
457
6.5 + 6.5
5.2 + 5.2
342
457
9.5 + 9.5
9.5 + 9.5
342
457
6.5 + 6.5
6.5 + 6.5
342
457
9.5 + 9.5
9.5 + 9.5
342
457
6.5 + 6.5
6.5 + 9.5
342
457
6.5 + 6.5
6.5 + 6.5
342
457
9.5 + 9.5
6.5 + 6.5
342
457
9.5 + 9.5
9.5 + 9.5
342
457
9.5 + 9.5
9.5 + 9.5
342
457
9.5 + 9.5
9.5 + 9.5
LRA
FLA
kW
Compressor
Compressor
Unit nr.2
Unit nr.3
Unit nr.4
LRA
RLA
LRA
RLA
4.6 + 4.6
5.2 + 5.2
5.2 + 5.2
5.2 + 5.2
6.5 + 6.5
5.2 + 5.2
5.2 + 5.2
6.5 + 6.5
5.2 + 5.2
5.2 + 5.2
6.5 + 6.5
5.2 + 5.2
5.2 + 5.2
9.5 + 9.5
6.5 + 6.5
5.2 + 5.2
6.5 + 6.5
6.5 + 6.5
6.5 + 6.5
6.5 + 6.5
6.5 + 6.5
6.5 + 6.5
9.5 + 9.5
6.5 + 6.5
9.5 + 9.5
9.5 + 9.5
: Locked Rotor Amps (vaste rotor amp)
: Full Load Amps (volle last amp)
: Nominaal uitgangsvermogen ventilatormotor (kW)
Ventilatormotor
kW
FLA
MCA MOCP ICF
0.60
0.8
16.5
0.60
0.8
16.5
0.60
1.0
20.0
0.60
1.1
22.5
0.60
1.1
24.5
Ventilatormotor
LRA
kW
FLA
MCA MOCP ICF
0.6 × 2 1.0 + 0.8
36.5
0.6 × 2 1.0 + 1.0
40.0
0.6 × 2 1.0 + 1.1
42.5
0.6 × 2 1.1 + 1.1
45.0
0.6 × 3 1.0 + 1.0 + 0.8
56.5
0.6 × 2 1.1 + 1.1
47.0
0.6 × 3 1.0 + 1.0 + 1.0
60.0
0.6 × 2 1.1 + 1.1
49.0
0.6 × 3 1.1 + 1.1 + 1.0
62.5
0.6 × 3 1.1 + 1.1 + 1.0
65.0
0.6 × 3 1.1 + 1.1 + 1.1
67.5
0.6 × 4 1.0 + 1.0 + 1.0 + 1.0 80.0
0.6 × 3 1.1 + 1.1 + 1.1
69.5
0.6 × 4 1.1 + 1.0 + 1.0 + 1.0 82.5
0.6 × 3 1.1 + 1.1 + 1.1
71.5
0.6 × 4 1.1 + 1.1 + 1.0 + 1.0 85.0
0.6 × 3 1.1 + 1.1 + 1.1
73.5
0.6 × 4 1.1 + 1.1 + 1.1 + 1.0 87.5
0.6 × 4 1.1 + 1.1 + 1.1 + 1.1 90.0
0.6 × 4 1.1 + 1.1 + 1.1 + 1.1 92.0
0.6 × 4 1.1 + 1.1 + 1.1 + 1.1 94.0
0.6 × 4 1.1 + 1.1 + 1.1 + 1.1 96.0
0.6 × 4 1.1 + 1.1 + 1.1 + 1.1 98.0
OPMERKING :
RLA is gebaseerd op de volgende omstandigheden.
Binnentemperatuur
: 27°C DB/19°C WB
buitentemperatuur
: 35°C DB
50Hz
Voeding
20
20
30
30
30
Voeding
40
50
50
60
70
60
70
60
70
80
80
90
80
100
80
100
90
100
100
110
110
110
110

Hide quick links: