Toshiba SUPER MMY-MAP0501T8 Instruction Manual page 10

Hide thumbs Also See for SUPER MMY-MAP0501T8:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 4
n Single outdoor unit
Heat Pump
Cooling
Nominal
Model
Only model
Voltage
MMY-
MMY-
(V-Ph-Hz)
MAP0501HT8 MAP0501T8 400-3-50
MAP0601HT8 MAP0601T8 400-3-50
MAP0801HT8 MAP0801T8 400-3-50
MAP1001HT8 MAP1001T8 400-3-50
MAP1201HT8 MAP1201T8 400-3-50
n Combination of outdoor unit
Heat Pump
Cooling
Nominal
Model
Only model
Voltage
MMY-
MMY-
(V-Ph-Hz)
AP1401HT8
AP1401T8
400-3-50
AP1601HT8
AP1601T8
400-3-50
AP1801HT8
AP1801T8
400-3-50
AP2001HT8
AP2001T8
400-3-50
AP2201HT8
AP2201T8
400-3-50
AP2211HT8
AP2211T8
400-3-50
AP2401HT8
AP2401T8
400-3-50
AP2411HT8
AP2411T8
400-3-50
AP2601HT8
AP2601T8
400-3-50
AP2801HT8
AP2801T8
400-3-50
AP3001HT8
AP3001T8
400-3-50
AP3201HT8
AP3201T8
400-3-50
AP3211HT8
AP3211T8
400-3-50
AP3401HT8
AP3401T8
400-3-50
AP3411HT8
AP3411T8
400-3-50
AP3601HT8
AP3601T8
400-3-50
AP3611HT8
AP3611T8
400-3-50
AP3801HT8
AP3801T8
400-3-50
AP4001HT8
AP4001T8
400-3-50
AP4201HT8
AP4201T8
400-3-50
AP4401HT8
AP4401T8
400-3-50
AP4601HT8
AP4601T8
400-3-50
AP4801HT8
AP4801T8
400-3-50
Legend
MCA
: Minimum Circuit Amps
MOCP
: Maximum Overcurrent Protection (Amps)
ICF
: Maximum Instantaneous Current Flow Start
RLA
: Rated Load Amps
Voltage
Range
Min
Max
RLA
LRA
342
457
4.0 + 4.0
342
457
4.6 + 4.6
342
457
5.2 + 5.2
342
457
6.5 + 6.5
342
457
9.5 + 9.5
Voltage
Range
Unit No.1
Unit No.2
Min
Max
RLA
LRA
RLA
342
457
5.2 + 5.2
4.6 + 4.6
342
457
5.2 + 5.2
5.2 + 5.2
342
457
6.5 + 6.5
5.2 + 5.2
342
457
6.5 + 6.5
6.5 + 6.5
342
457
5.2 + 5.2
5.2 + 5.2
342
457
9.5 + 9.5
6.5 + 6.5
342
457
5.2 + 5.2
5.2 + 5.2
342
457
9.5 + 9.5
9.5 + 9.5
342
457
6.5 + 6.5
5.2 + 5.2
342
457
6.5 + 6.5
6.5 + 6.5
342
457
6.5 + 6.5
6.5 + 6.5
342
457
5.2 + 5.2
5.2 + 5.2
342
457
9.5 + 9.5
6.5 + 6.5
342
457
6.5 + 6.5
5.2 + 5.2
342
457
9.5 + 9.5
9.5 + 9.5
342
457
6.5 + 6.5
6.5 + 6.5
342
457
9.5 + 9.5
9.5 + 9.5
342
457
6.5 + 6.5
6.5 + 9.5
342
457
6.5 + 6.5
6.5 + 6.5
342
457
9.5 + 9.5
6.5 + 6.5
342
457
9.5 + 9.5
9.5 + 9.5
342
457
9.5 + 9.5
9.5 + 9.5
342
457
9.5 + 9.5
9.5 + 9.5
LRA
: Locked Rotor Amps
FLA
: Full Load Amps
kW
: Fan Motor Rated Output (kW)
Compressor
Compressor
Unit No.3
Unit No.4
LRA
RLA
LRA
RLA
LRA
4.6 + 4.6
5.2 + 5.2
5.2 + 5.2
5.2 + 5.2
6.5 + 6.5
5.2 + 5.2
5.2 + 5.2
6.5 + 6.5
5.2 + 5.2
5.2 + 5.2
6.5 + 6.5
5.2 + 5.2
5.2 + 5.2
9.5 + 9.5
6.5 + 6.5
5.2 + 5.2
6.5 + 6.5
6.5 + 6.5
6.5 + 6.5
6.5 + 6.5
6.5 + 6.5
6.5 + 6.5
9.5 + 9.5
6.5 + 6.5
9.5 + 9.5
9.5 + 9.5
Fan Motor
Power Supply
kW
FLA
MCA MOCP ICF
0.60
0.8
16.5
0.60
0.8
16.5
0.60
1.0
20.0
0.60
1.1
22.5
0.60
1.1
24.5
Fan Motor
Power Supply
kW
FLA
MCA MOCP ICF
0.6 × 2 1.0 + 0.8
36.5
0.6 × 2 1.0 + 1.0
40.0
0.6 × 2 1.0 + 1.1
42.5
0.6 × 2 1.1 + 1.1
45.0
0.6 × 3 1.0 + 1.0 + 0.8
56.5
0.6 × 2 1.1 + 1.1
47.0
0.6 × 3 1.0 + 1.0 + 1.0
60.0
0.6 × 2 1.1 + 1.1
49.0
0.6 × 3 1.1 + 1.1 + 1.0
62.5
0.6 × 3 1.1 + 1.1 + 1.0
65.0
0.6 × 3 1.1 + 1.1 + 1.1
67.5
0.6 × 4 1.0 + 1.0 + 1.0 + 1.0
80.0
0.6 × 3 1.1 + 1.1 + 1.1
69.5
0.6 × 4 1.1 + 1.0 + 1.0 + 1.0
82.5
100
0.6 × 3 1.1 + 1.1 + 1.1
71.5
0.6 × 4 1.1 + 1.1 + 1.0 + 1.0
85.0
100
0.6 × 3 1.1 + 1.1 + 1.1
73.5
0.6 × 4 1.1 + 1.1 + 1.1 + 1.0
87.5
100
0.6 × 4 1.1 + 1.1 + 1.1 + 1.1
90.0
100
0.6 × 4 1.1 + 1.1 + 1.1 + 1.1
92.0
0.6 × 4 1.1 + 1.1 + 1.1 + 1.1
94.0
0.6 × 4 1.1 + 1.1 + 1.1 + 1.1
96.0
0.6 × 4 1.1 + 1.1 + 1.1 + 1.1
98.0
NOTE :
RLA is based on the following conditions.
Indoor temperature
: 27°C DB/19°C WB
Outdoor temperature : 35°C DB
50Hz
20
20
30
30
30
40
50
50
60
70
60
70
60
70
80
80
90
80
80
90
110
110
110
110

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents