When Error Occurs At Start Of Operation - Hitachi UX2 Instruction Manual

Hide thumbs Also See for UX2:
Table of Contents

Advertisement

4.2.2. When Error Occurs at Start of Operation

When an error occurs at the start of operation, use the following procedure.
1
Make sure that the unit is in the [Stop] state.
2
Loosen the head cover lock screw and remove the print head cover.
Head cover lock screw
Loosen to remove the print
head cover.
3
Clean inside the area to be cleaned with makeup.
Clean the nozzle orifice, charge electrode, deflection electrode, and gutter with makeup. (Also, see "3.3.
Print Head Cleaning").
Cleaning bottle
* Wipe the makeup on the surface of each part (including the mounting base) thoroughly with wiping
paper and dry the part.
Print head cover
Deflection electrode
Beaker
Chapter 4. Basic Operation
Pull out
Charge electrode
Gutter
Area to be cleaned
Nozzle orifice
4-17