Settings used
For the configuration example, the devices are given the following IP address settings:
Device
SINEMA RC server
(PC1a)
Router 1 (R1)
PC
(PC1b)
Service technician
(PC2)
Router 2
SCALANCE M874-3
CPU 317
Use a PC to configure the SCALANCE M804PB and the SINEMA RC server. To do so, you must
assign the IP address to the PC network adapter. In the extended TCP/IP settings of the
network adapter configuration you have the option of adding additional IP addresses.
Note
The IP settings used in the configuration example were freely chosen.
In a real network, you would need to adapt these IP settings to avoid possible address
conflicts.
Cloud Connector
Getting Started, 07/2020, C79000-G8976-C507-03
Interface
IP address
LAN port
192.168.0.150
255.255.255.0
WAN port
192.168.20.150
255.255.255.0
The WAN IP address via which the SINEMA RC server can be
reached is the WAN IP address of the router in this example,
192.168.203.150.
Default gateway is the LAN IP address of the router
192.168.20.2
LAN port
192.168.20.2
255.255.255.0
WAN port
Static IP address assigned by provider, e.g. 192.168.203.150
LAN port
192.168.0.20
(vlan1)
255.255.255.0
192.168.5.1
255.255.255.0
Default gateway is the LAN IP address of the router
192.168.5.2
LAN port
192.168.5.2
255.255.255.0
WAN port
Dynamic IP address from the provider
LAN port
192.168.16.84
(vlan1)
255.255.255.0
ppp0
Dynamic IP address from the provider
-
192.168.16.31
PROFINET connection
3.2 Remote service