Siemens SIMATIC NET SCALANCE M80PB Getting Started page 41

Industrial remote communication remote networks cloud connector
Table of Contents

Advertisement

Settings used
For the configuration example, the devices are given the following IP address settings:
Device
PG/PC
SCALANCE M874-3
You configure SCALANCE M874-3 with the programming device / PC via Web Based
Management. To do so, you must assign the IP address to the PC network adapter. In the
extended TCP/IP settings of the network adapter configuration you have the option of adding
additional IP addresses.
Note
You can also use another SCALANCE M-800/S615 device. The configuration described below
relates to the SCALANCE M874-3.
Note
The IP settings used in the configuration example were freely chosen.
In a real network, you would need to adapt these IP settings to avoid possible address
conflicts.
Requirement
• SCALANCE M874-3
– Firmware version 6.3
– The device is accessible via the PG/PC and you are logged on to the WBM as
– The device is connected to the CPU via the PNI interface.
• PG/PC
– TIA Portal V15 Update 4 is installed.
Steps in configuration
The following steps are required to read out the diagnostic buffer:
1. Enabling the integrated TIA Portal Cloud Connector on the device (Page 42)
2. Enabling the TIA Portal Cloud Connector on the PG/PC (Page 43)
3. Connecting to the TIA Portal Cloud Connector (Page 45)
Cloud Connector
Getting Started, 07/2020, C79000-G8976-C507-03
VLAN
VLAN1
P1 (VLAN1)
"Administrator".
You can find more information on this in the "SCALANCE M-800 Getting Started
(https://support.industry.siemens.com/cs/ww/en/view/78389746)".
IP address
192.168.16.10
255.255.255.0
192.168.16.84
255.255.255.0
PROFINET connection
3.1 Local service
41