FURNACE MULTIPLIERS - 3 TON (Continued)
Furnaces
Coil
CP9C120D20MP12C
CF/CM/CU48D
CP9C120D20MP13C
CF/CM/CU48D
CPLC080B12MP12C
CF/CM/CU48C
CPLC080B12MP13C
CF/CM/CU48C
CPLC080C16MP12C
CF/CM/CU48C
CPLC080C16MP12C
CF/CM/CU48D
CPLC080C16MP13C
CF/CM/CU48C
CPLC080C16MP13C
CF/CM/CU48D
CPLC100C16MP12C
CF/CM/CU48C
CPLC100C16MP12C
CF/CM/CU48D
CPLC100C16MP13C
CF/CM/CU48C
HEATING PERFORMANCE DATA
CONDENSING UNIT MODEL NO
AIR TEMP.
ENTERING
OUTDOOR UNIT (°F)
INDOOR COIL (°F)
60
47
40
30
17
10
0
-10
-20
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT. KW VALUES ARE FOR THE SYSTEM (OUTDOOR + INDOOR).
Yellow shaded cells are AHRI High Heating conditions.
Orange shaded cells are AHRI Low Heating conditions.
Multipliers for determining the performance with other indoor sections.
Johnson Controls Ducted Systems
T.C.
S.C.
1.00
1.04
1.00
1.04
1.00
1.05
1.00
1.05
1.00
1.08
1.00
1.03
1.00
1.08
1.00
1.03
1.00
1.08
1.00
1.03
1.00
1.08
TH4B3622S
AIR TEMP.
ENTERING
MBH
60
40.6
70
39.9
80
39.1
60
35.3
70
34.8
80
34.3
60
33.2
70
32.5
80
31.9
60
28.2
70
27.9
80
27.6
60
23.1
70
22.5
80
21.8
60
19.5
70
19.4
80
19.4
60
16.0
70
16.0
80
16.0
60
12.0
70
12.0
80
11.9
60
7.9
70
7.9
80
7.9
FURNACE MULTIPLIERS - 3 TON (Continued)
KW
Furnaces
0.92
CPLC100C16MP13C
0.92
CPLC100C20MP12C
0.96
CPLC100C20MP12C
0.96
CPLC100C20MP13C
0.93
CPLC100C20MP13C
0.92
CPLC120C20MP12C
0.93
CPLC120C20MP12C
0.92
CPLC120C20MP13C
0.93
CPLC120C20MP13C
0.92
0.93
1000
COP
KW
MBH
4.12
2.88
41.2
3.70
3.19
40.4
3.27
3.50
39.7
3.73
2.77
35.9
3.34
3.08
35.3
2.96
3.40
34.7
3.55
2.74
33.5
3.17
3.04
32.9
2.79
3.34
32.3
3.11
2.66
28.9
2.80
2.96
28.5
2.49
3.25
28.1
2.66
2.55
23.2
2.36
2.82
22.7
2.06
3.10
22.1
2.25
2.54
19.8
2.07
2.76
19.8
1.90
2.99
19.7
1.92
2.43
16.3
1.77
2.65
16.3
1.62
2.87
16.2
1.47
2.38
12.2
1.35
2.59
12.2
1.24
2.80
12.1
0.99
2.32
8.1
0.92
2.53
8.0
0.84
2.73
8.0
5523951-CTG-J-0620
Coil
T.C.
CF/CM/CU48D
1.00
CF/CM/CU48C
1.00
CF/CM/CU48D
1.00
CF/CM/CU48C
1.00
CF/CM/CU48D
1.00
CF/CM/CU48C
1.00
CF/CM/CU48D
1.00
CF/CM/CU48C
1.00
CF/CM/CU48D
1.00
ID CFM
1200
COP
KW
MBH
4.26
2.83
41.8
3.84
3.12
41.0
3.42
3.41
40.2
3.86
2.73
36.5
3.46
3.03
35.8
3.06
3.33
35.0
3.64
2.70
33.8
3.26
2.99
33.3
2.89
3.28
32.8
3.20
2.64
29.5
2.89
2.92
29.0
2.57
3.20
28.5
2.69
2.53
23.4
2.40
2.80
22.9
2.11
3.08
22.4
2.28
2.55
20.2
2.10
2.77
20.1
1.92
3.00
20.0
1.94
2.44
16.6
1.79
2.66
16.5
1.64
2.87
16.4
1.49
2.39
12.4
1.37
2.60
12.4
1.26
2.81
12.3
1.01
2.33
8.2
0.93
2.53
8.2
0.85
2.74
8.1
S.C.
KW
1.03
0.92
1.08
0.92
1.08
0.92
1.08
0.92
1.08
0.92
1.08
0.92
1.08
0.92
1.08
0.92
1.08
0.92
1400
COP
KW
4.40
2.78
3.98
3.05
3.56
3.31
3.99
2.68
3.57
2.97
3.15
3.25
3.72
2.66
3.35
2.94
2.99
3.22
3.30
2.62
2.97
2.89
2.65
3.15
2.72
2.51
2.44
2.79
2.15
3.06
2.31
2.55
2.13
2.78
1.95
3.01
1.97
2.45
1.82
2.67
1.66
2.88
1.51
2.39
1.39
2.61
1.27
2.82
1.02
2.33
0.94
2.54
0.86
2.75
161