5523951-CTG-J-0620
HEATING PERFORMANCE DATA
CONDENSING UNIT MODEL NO
AIR TEMP.
ENTERING
OUTDOOR UNIT (°F)
INDOOR COIL (°F)
60
47
40
30
17
10
0
-10
-20
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT. KW VALUES ARE FOR THE SYSTEM (OUTDOOR + INDOOR).
Yellow shaded cells are AHRI High Heating conditions.
Orange shaded cells are AHRI Low Heating conditions.
Multipliers for determining the performance with other indoor sections.
\
COIL MULTIPLIERS - 2 TON
Air Handler
Coil
CF/CM/CU24A
CF/CM/CU24B
CF/CM/CU30A
CF/CM/CU30B
CF/CM/CU30D
CF/CM24C
CF/CM30C
CF24ABAA1
CF24BBAA1
CF30ABAA1
CF30BBAA1
CM24ABAA1
CM24BBAA1
CM30BBAA1
AE24BBA21
AE24BX21
AE30BX21
AP24BBA21
124
TH4B2421S
AIR TEMP.
ENTERING
MBH
60
29.5
70
28.6
80
27.8
60
25.1
70
24.3
80
23.6
60
22.7
70
22.1
80
21.4
60
19.8
70
19.2
80
18.7
60
15.3
70
14.7
80
14.1
60
13.4
70
13.0
80
12.7
60
9.9
70
9.6
80
9.4
60
6.7
70
6.5
80
6.4
60
3.6
70
3.5
80
3.4
MBH
COP
1.00
0.97
1.00
1.00
1.00
1.03
1.00
1.06
1.00
1.06
1.00
1.00
1.00
1.06
1.00
0.97
1.00
1.00
1.00
1.03
1.00
1.06
1.00
0.97
1.00
1.00
1.00
1.06
1.00
1.03
1.00
1.03
1.00
1.14
1.00
1.00
600
COP
KW
MBH
3.98
2.17
30.4
3.51
2.39
29.7
3.11
2.62
29.0
3.56
2.06
26.0
3.13
2.28
25.2
2.76
2.51
24.4
3.33
2.00
23.4
2.91
2.22
22.8
2.57
2.44
22.2
2.98
1.94
20.2
2.62
2.15
19.7
2.33
2.36
19.1
2.44
1.83
15.9
2.12
2.03
15.2
1.86
2.23
14.5
2.21
1.78
14.0
1.94
1.97
13.5
1.71
2.17
13.0
1.71
1.69
10.3
1.50
1.87
10.0
1.33
2.06
9.6
1.20
1.65
7.0
1.05
1.82
6.8
0.93
2.01
6.5
0.65
1.60
3.7
0.57
1.77
3.6
0.50
1.95
3.4
COIL MULTIPLIERS - 2 TON
Air Handler
KW
AP24BX21
1.07
AP30BX21
1.04
AVC24BX21
1.00
AVC30BX21
1.00
ME08BN21
0.95
ME08BN21
1.00
ME08BN21
0.95
ME08BN21
1.07
ME08BN21
1.04
ME08BN21
1.00
ME12BN21
1.00
ME12BN21
1.07
ME12BN21
1.04
ME12BN21
1.00
ME12BN21
0.98
ME12BN21
0.98
ME12CN21
0.87
ME14DN21
1.00
ID CFM
800
COP
KW
MBH
4.33
2.06
31.4
3.82
2.28
30.8
3.41
2.49
30.1
3.83
1.99
26.9
3.36
2.20
26.1
2.97
2.41
25.3
3.51
1.95
24.0
3.11
2.15
23.5
2.75
2.36
23.0
3.12
1.90
20.7
2.74
2.10
20.1
2.43
2.30
19.4
2.54
1.83
16.5
2.21
2.01
15.7
1.93
2.19
14.8
2.29
1.79
14.63
2.01
1.97
14.0
1.77
2.15
13.3
1.78
1.70
10.8
1.56
1.87
10.3
1.37
2.05
9.8
1.24
1.66
7.3
1.09
1.82
7.0
0.96
1.99
6.7
0.68
1.61
3.9
0.59
1.77
3.7
0.52
1.93
3.5
Coil
MBH
1.00
1.00
1.00
1.00
CF/CM24B
1.00
CF/CM30B
1.00
CF24BBAA1
1.00
CF30BBAA1
0.99
CM24BBAA1
0.98
CM30BBAA1
0.99
CF/CM24B
1.00
CF/CM30B
1.00
CF24BBAA1
1.00
CF30BBAA1
1.00
CM24BBAA1
0.98
CM30BBAA1
1.00
CF/CM24C
1.00
CF/CM30D
1.00
Johnson Controls Ducted Systems
1000
COP
KW
4.69
1.96
4.17
2.16
3.74
2.36
4.13
1.91
3.60
2.12
3.19
2.32
3.73
1.89
3.29
2.09
2.95
2.28
3.25
1.87
2.87
2.05
2.54
2.24
2.64
1.83
2.30
1.99
2.01
2.16
2.39
1.79
2.09
1.96
1.83
2.13
1.86
1.70
1.62
1.86
1.42
2.03
1.30
1.66
1.13
1.81
0.99
1.97
0.70
1.61
0.61
1.76
0.54
1.92
COP
KW
1.00
1.00
1.09
0.92
1.01
1.01
1.15
0.87
1.07
0.95
1.15
0.87
1.07
0.95
1.14
0.87
1.06
0.92
1.14
0.87
1.03
0.98
1.11
0.90
1.03
0.98
1.13
0.88
1.06
0.92
1.13
0.88
0.99
1.03
1.11
0.90

Advertisement

Table of Contents
loading

Table of Contents