Operation Manual / Power2 340-H / Low-pressure stage
7 Periodic maintenance / 7.4 Cleaning turbine and nozzle ring during
operation
(see Fig. 19: Cleaning the filter silencer →56)
Dismantling and cleaning the cover grid (81266)
Loosen the tension bands (81270).
u
Remove and clean cover grid (81266).
u
Cleaning the absorption segments (81136)
Pull out and bend up the sheet-metal coverings (81137), and remove the absorption seg-
u
ments (81136).
Clean the absorption segments.
u
When cleaning, note that the absorption segments may only be cleaned lightly with pres-
surized air, a soft brush or a moist cleaning cloth.
Have any heavily contaminated absorption segment replaced by a Turbo Systems service
u
station.
Fitting the filter silencer
Insert the absorption segments (81136) into the sheet-metal coverings (81137).
u
Bend the sheet-metal coverings (81137) back to their original shape and insert into the
u
slotted guides in the filter silencer body (81135).
Fit the cover grid (81266).
u
Fit the tension bands (81270) and tighten them at the locks (81271).
u
Any tension bands that have become damaged must be replaced.
Fit the filter ring (81265), if present.
u
7.4

Cleaning turbine and nozzle ring during operation

Power2 340-H is carried out without turbine cleaning function.