6 Operation and service / 6.2 Service work
6.2.3
Service work according to instructions of enginebuilder
Clean or replace the oil filter located in the supply pipe to the low-pressure and high-pres-
u
sure stage while the engine is stopped.
6.2.4
Service work every 10000 ... 20000 hours
The rotor and bearing parts must be checked and assessed by a Turbo Systems service sta-
tion.
Remove low-pressure and high-pressure stage from the engine and dismantle according
u
to chapter Disassembly and assembly. Measure clearances.
Clean nozzle ring, turbine casing, and compressor casing, and check for cracks and
u
erosion/corrosion.
6.2.5
Entries in the engine logbook
The monitoring of the engine enables conclusions to be drawn on the behaviour of the low-
pressure and high-pressure stage.
The following operating data and measured values must be entered regularly in the engine
logbook of the enginebuilder:
¡
Performance and speed of the engine
¡
Air intake temperature
¡
Pressure of the charge air
¡
Pressure loss in the charge air cooler and intercooler
¡
Lubricating oil pressure and lubricating oil temperature
If present:
¡
Speed of low-pressure and high-pressure stage
¡
Air temperature before and after the compressor and after the charge air cooler
¡
Exhaust gas temperature before and after the turbine
¡
Atmospheric humidity of the suction air (before the low-pressure stage)