Removing The Gas Outlet Casing And Gas Outlet Flange; Fig. 22: Removing The Gas Outlet Casing And Gas Outlet Flange; Table 41: Press-Off Screws To Be Used - ABB PT003924 Operation Manual

Low-pressure stage
Table of Contents

Advertisement

Operation Manual / Power2 340-H / Low-pressure stage
9 Disassembly and assembly / 9.4 Removing the gas outlet casing and
gas outlet flange
9.4
Removing the gas outlet casing and gas outlet
flange
Fig. 22: Removing the gas outlet casing and gas outlet flange
1. Loop around the gas outlet casing (61001) with lifting gear.
2. Remove screw (61003) with Verbus Ripp® washer (61004) and support (61300).
3. Loosen nuts (51009) and remove with Verbus Ripp® washers (51004).
4. Remove the gas outlet casing (61001).
5. Remove the gasket (61002).
6. Measure radial clearance (R) (see chapter
7. Press off the gas outlet flange (57002) with screws (S) according to the following table.
Table 41: Press-off screws to be used
*not included in the Turbo Systems. scope of delivery.
© Copyright 2022 ABB. All rights reserved.
Measuring radial clearances N and R
Press-off screws to be used (strength 8.8)*
6x M10
HZTL4053_EN
→72)
Rev.F
March 2022