(b) In case of RC-E5 remote control
Operation data can be checked with remote control unit
operation.
➀ Press the
button.
The display change "
➁ Press the
(SET) button while "
displayed.
➂ When only one indoor unit is connected to remote control,
"
" is displayed (blinking indication during
data loading).
Next, operation data of the indoor unit will be displayed.
Skip to step ➆.
➃ When plural indoor units is connected, the smallest
address number of indoor unit among all connected indoor
unit is displayed.
[Example]:
"
" (blinking 1 seconds) ➝ "
blinking.
➄ Select the indoor unit number you would like to have data
displayed with the
➅ Determine the indoor unit number with the
button.
(The indoor unit number changes from blinking indication
to continuous indication)
"
" (The address of selected indoor unit is blinking
for 2 seconds.)
"
" (A blinking indication appears while data loaded.) Next, the operation data of the indoor unit are
indicated.
➆ Upon operation of the
The items displayed are in the above table.
*Depending on models, the items that do not have corresponding data are not displayed.
➇ To display the data of a different indoor unit, press the
indoor unit selection screen.
➈ Pressing the
Pressing the
(RESET) button during remote control unit operation will undo your last operation and allow
you to go back to the previous screen.
 I f two (2) remote controls are connected to one (1) inside unit, only the master control is available for trial
operation and confirmation of operation data. (The slave remote control is not available.)
Number 33 Details of compressor protection status No.
Refer to page 60.
"
button.
(SET)
button, the current operation data are displayed in order from data number 01.
button will stop displaying data.
61
-
-
Number
01
02
03
04
05
06
" is
07
08
09
10
11
12
21
22
23
24
25
26
27
28
29
"
30
31
32
33
34
35
36
37
38
39
button, which allows you to go back to the
'19 • PAC-SM-334
Data Item
(Operation Mode)
(Set Temperature)
(Return Air Temperature)
(Remote Control Temperature Sensor Tempeature)
(Indoor Heat Exchanger Temperature Sensor / U Bend)
(Indoor Heat Exchanger Temperature Sensor /Capillary)
(Indoor Heat Exchanger Temperature Sensor /Gas Header)
(Indoor Unit Fan Speed)
(Frequency Requirements)
(Response Frequency)
(Pulse of Indoor Unit Expansion Value)
(Total Running Hours of The Indoor Unit)
(Outdoor Air Temperature)
(Outdoor Heat Exchanger Temperature Sensor)
(Outdoor Heat Exchanger Temperature Sensor)
(Compressor Frequency)
(High Pressure)
(Low Pressure)
(Discharge Pipe Temperature)
(Compressor Bottom Temperature)
(Current)
(Target Super Heat)
(Super Heat)
(Discharge Pipe Super Heat)
(Protection State No. of The Compressor)
(Outdoor Unit Fan Speed)
(63H1 On/Off)
(Defrost Control On/Off)
(Total Running Hours of The Compressor)
(Pulse of The Outdoor Unit Expansion Valve EEVC)
(Pulse of The Outdoor Unit Expansion Valve EEVH)