Battery: Connecting To A Stationary Battery Charging Unit For Sustained Charging - Audi A8 2010 Maintenance Manual

Hide thumbs Also See for A8 2010:
Table of Contents

Advertisement

Audi A8 2010 ➤
Maintenance - Edition 11.2014
– Before checking electrolyte level: Tap magic eye -arrow- care‐
fully with handle of a screwdriver.
– Read off battery electrolyte level according to colour display.
Two different results are possible:
Colour of magic eye:
Black or green
Colourless or light yellow
Install in reverse sequence.
Note
The magic eye is also referred to as an ALI (acid level indica‐
tor).
The magic eye is only for use in determining the electrolyte
level.
During battery charging or vehicle operation, air bubbles can
form underneath the magic eye which could falsify the colour
display. Tap magic eye lightly to release any bubbles.
3.9
Battery: connecting to a stationary bat‐
tery charging unit for sustained charging
DANGER!
Risk of fatal injury if high-voltage components are damaged.
Protected by copyright. Copying for private or commercial purposes, in part or in whole, is not
permitted unless authorised by AUDI AG. AUDI AG does not guarantee or accept any liability
♦ Observe warnings for high-voltage system:
with respect to the correctness of information in this document. Copyright by AUDI AG.
♦ Handling high-voltage wires
♦ For work in the vicinity of high-voltage components
⇒ page 10
.
WARNING
Risk of injury if battery terminal clamps are connected incor‐
rectly.
♦ Connect positive battery terminal clamp first, then connect
negative battery terminal clamp.
Special tools and workshop equipment required
34
3. Maintenance
Measure:
Electrolyte level OK: No further measures necessary
Electrolyte level too low: Battery must be renewed
⇒ page 11
.