Annex I Examples of Simple Application

1. Disturbance function (triangular wave achievement)
(1) Achieve those shown in F-1 curve.
(2) Parameter setting P080=5 P003=30 P086=27 P092=0.5 P101=10 P102=10
2. Realization of drafting function
As shown in the curve of Figure F-2.
Figure F-2 Drafting Function Curve and Wiring Diagram
Parameter setting
[Description] 1) Enable drafting via triggering external multi-function terminal (RST
selected as shown in the diagram);
2) While drafting is enabled, operating time T is P101×10s.
3. Forward/reverse rotation of motor in the control of potentiometer

Annex

Figure F-1 Disturbance Function Curve
P080=4
P003=25
P101=720
P046=29
P086=50
P087=30
P001=1