Description Of Control Terminals; Description Of Jumper Function - DEMA D5M Series Manual

Table of Contents

Advertisement

NO.3 Wiring

3.4 Description of control terminals

Symbol of
terminal
X1
X2
X3
Multi-function
terminals 1-6
X4
X5
X6
Digital/analog/communication
GND
and power earthing terminals
12V
+12V power supply
AI1
Analog voltage input
Analog
AI2
selecting via jumper1, default to
current input
A0
Analog voltage output
FA、 FB、 FC
Multi-function relay output
RS+ RS-
RS485 communication interface

3.5 Description of jumper function

No.
J1
J2
Wiring mode of multi-function digital input terminals X1-X6:
(1) When NPN type wiring mode is adopted for external equipment, leakage type logic is
induced and the current flows out from input terminal (sourcing current) as shown in Figure
3-1, at the same time parameter P067=0 is required.
8
Function of terminal
digital
current/voltage
Function
Selection of AI2 input type
V: Voltage mode mA: Current mode
Selection of X1-X6 wiring mode
NPN type or PNP type
Set as forward during delivery
Set as reverse during delivery
Set as reset during delivery
input
Set as high speed during delivery
Set as medium speed during delivery
Set as low speed during delivery
Isolation of GND inside from PE
Maximum output current: 150mA
Input voltage range: 0-+10V
input,
Input current range: 0-+20mA
Input voltage range: 0-+10V
Output voltage range: 0-+10V
FA-FC:
normally closed
Contact specification: 250VAC/3A,
30VDC/3A
Available connection of 1-32 RS485
sites
Description
normally
open,
Ex-factory setting
mA
NPN
FB-FC: