Download Print this page

Brother DCP-7090 Service Manual page 32

Laser mfc
Hide thumbs Also See for DCP-7090:

Advertisement

Error message
Upper line
Print Data Full Print Data is full.
Press Stop[x] and
delete the
previously stored
data.
Print Unable
Turn the power off
01
and then back on
again.
Print Unable
Turn the power off
02
and then back on
again.
Print Unable
Turn the power off
03
and then back on
again.
Print Unable
Turn the power off
04
and then back on
again.
Print Unable
Turn the power off
05
and then back on
again.
Print Unable
Turn the power off
09
and then back on
again.
Print Unable
Turn the power off
0A
and then back on
again.
Lower line
The memory used to store
secure print data exceeded the
memory size for secure print
data.
 ASIC error or motor driver error
occurred.
Cannot detect the synchronized
signal of the paper feed motor.
The speed of the paper feed
motor does not stabilize within
the specified time.
Cannot detect the lock signal of
the polygon motor for the laser
unit. (second time)
BD sensor failure (second time)
Detected the fuser unit
temperature error.
Detected irregular power supply
for more than 100 times.
Detected a fan failure.
Error
Description
codes
C800
0102
0201
0300
0401
0501
0502
0503
0504
0505
0506
0508
050A
050B
050C
0900
0A02
Refer
to:
2-70
2-47
2-47
2-47
2-48
2-49
2-49
2-49
2-49
2-49
2-49
2-49
2-49
2-49
2-49
2-50
2-50

Advertisement