System Charge For Various Matched Systems - Coleman LX Series Technical Manual

Split system air conditioners 13 seer – r-410a – 1 phase 1.5 thru 5 nominal tons
Hide thumbs Also See for LX Series:
Table of Contents

Advertisement

5581710-CTG-C-0619

SYSTEM CHARGE FOR VARIOUS MATCHED SYSTEMS

Outdoor Unit
1,2
Required Orifice or TXV
3,4,5
Indoor Unit
AP18B
AP24B
AP30B
AP36B
AP36C
AP37C
AP42C
AP48C
AP48D
AP60(C,D)
AE18B
AE24B
AE30B
AE36(B,C)
AE42C
AE48(C,D)
AE60C
AE60D
AVC18B
AVC24B
AVC30B
AVC36(B,C)
AVC42C
AVC48(C,D)
AVC60C
AVC60D
CF/CM/CU18(A,B)
CF/CM/CU24(A,B)
CF/CM/CU30(A,B,C)
CF/CM/CU36(A,B,C,D)
CF/CM/CU42(B,C,D)
CF/CM/CU48(C,D)
CF/CM/CU60(C,D)
CF/CM64D
Some of the combinations shown in the above System Charge table require Advanced Main Air Circulating Fan indoor product. For approved coil
only matches, please see the "COOLING CAPACITY - Upflow, Downflow & Horizontal Furnaces and Coils" table.
FOOTNOTES:
1. For applications requiring a TXV, use S1-1TVM*** series kit.
2. Approved orifice(s) shipped with outdoor unit.
3. Systems matched with furnaces or air handlers not equipped with blower-off delays may require 60 second time delay.
4. CF coils cannot be used in horizontal applications.
5. Charge adders shown above do not indicate that coils are rated for every application. Refer to Performance Data Tables for actual performance for specified sys-
tem matches. Obtain certified system ratings from
CHARGING PROCEDURES:
1. Check the Factory Unit Charge listed on the unit nameplate to verify the refrigerant charge for the outdoor unit, the smallest matched indoor unit, and the 15 feet of
interconnecting lineset.
2. Verify the indoor metering device and additional charge required for the specific matched indoor unit in the system using the above table.
3. Add additional charge for the amount of interconnecting lineset tubing greater than 15 feet at the rate specified in Physical and Electrical Data Table.
4. For installations requiring additional charge, weigh in refrigerant for the specific matching indoor unit and actual lineset length.
5. Once the charge adders for matched indoor unit and for lineset have been weighed in, verify the system operation against the temperatures and pressures in the
Charging Chart for the outdoor unit. Locate Charging Charts on the outdoor unit and also in the Service Data Application Guide on
www.simplygettingthejobdone.com.
in the system, and allow ten minutes after each charge adjustment for the system operation to stabilize. Record the charge adjustment made to match the Charging
Chart.
6. Permanently stamp the unit nameplate with the TOTAL SYSTEM CHARGE defined as follows: TOTAL SYSTEM CHARGE = Base Charge (as shipped) + charge
adder for matched indoor unit + charge adder for actual lineset length + charge adjustments to match the Charging Chart.
4
TC3B1822S
TC3B2422S
0.049 / BH1
0.057 / BH1
0
3
0
7
0
3
0
8
5
7
0
3
0
8
5
7
0
3
0
8
5
10
7
11
www.ahridirectory.org.
Follow the Subcool or Superheat charging procedure in the Installation Manual according to the type of indoor metering device
TC3B3022S
TC3B3622S
0.061 / BA1
0.070 / BA1
Additional Charge, oz
2
0
2
2
5
5
0
2
0
5
5
0
2
0
5
5
0
2
0
2
2
5
TC3B4222S
TC3B4821S
0.075 / BC1
0.077 / BC1
2
0
2
0
2
2
2
0
9
2
29 oz TXV ONLY 22 oz TXV ONLY 20 oz TXV ONLY
2
2
0
2
29 oz TXV ONLY 22 oz TXV ONLY 20 oz TXV ONLY
0
2
0
9
2
29 oz TXV ONLY 22 oz TXV ONLY 20 oz TXV ONLY
Johnson Controls Ducted Systems
TC3B6021S
0.084 / BD1
0
0
0
0

Advertisement

Table of Contents
loading

Table of Contents