Coleman LX Series Technical Manual page 62

Split system air conditioners 13 seer – r-410a – 1 phase 1.5 thru 5 nominal tons
Hide thumbs Also See for LX Series:
Table of Contents

Advertisement

5581710-CTG-C-0619
COOLING CAPACITY - With High Efficiency Motor Furnaces
UNIT
MODEL
TC3B4821S
TL9E080C16UH11
TC3B4821S
TL9E080C16UH11
TC3B4821S
TL9E080C16UH11
TC3B4821S
TL9E080C16UH11
TC3B4821S
TL9E100C20UH11
TC3B4821S
TL9E100C20UH11
TC3B4821S
TL9E100C20UH11
TC3B4821S
TL9E100C20UH11
TC3B4821S
TM8E080B12MP11
TC3B4821S
TM8E080B12MP11
TC3B4821S
TM8E080C16MP11
TC3B4821S
TM8E080C16MP11
TC3B4821S
TM8E080C16MP11
TC3B4821S
TM8E080C16MP11
TC3B4821S
TM8E080C16MP11
TC3B4821S
TM8E080C20MP11
TC3B4821S
TM8E080C20MP11
TC3B4821S
TM8E080C20MP11
TC3B4821S
TM8E080C20MP11
TC3B4821S
TM8E080C20MP11
TC3B4821S
TM8E100C16MP11
TC3B4821S
TM8E100C16MP11
TC3B4821S
TM8E100C16MP11
TC3B4821S
TM8E100C16MP11
TC3B4821S
TM8E100C16MP11
TC3B4821S
TM8E100C20MP11
TC3B4821S
TM8E100C20MP11
TC3B4821S
TM8E100C20MP11
TC3B4821S
TM8E100C20MP11
TC3B4821S
TM8E100C20MP11
TC3B4821S
TM8E120C16MP11
TC3B4821S
TM8E120C16MP11
TC3B4821S
TM8E120C16MP11
TC3B4821S
TM8E120C16MP11
TC3B4821S
TM8E120C16MP11
TC3B4821S
TM8E120C20MP11
TC3B4821S
TM8E120C20MP11
TC3B4821S
TM8E120C20MP11
TC3B4821S
TM8E120C20MP11
TC3B4821S
TM8E120C20MP11
TC3B4821S
TM8E130D20MP11
TC3B4821S
TM8E130D20MP11
TC3B4821S
TM8E130D20MP11
TC3B4821S
TM8V080C16MP11C
TC3B4821S
TM8V080C16MP11C
TC3B4821S
TM8V080C16MP11C
TC3B4821S
TM8V080C16MP11C
TC3B4821S
TM8V080C16MP11C
TC3B4821S
TM8V080C16MP12C
TC3B4821S
TM8V080C16MP12C
TC3B4821S
TM8V080C16MP12C
TC3B4821S
TM8V080C16MP12C
TC3B4821S
TM8V080C16MP12C
62
FURNACE
MODEL
WIDTH
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
17.5
17.5
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
24.5
24.5
24.5
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
21.0
1
(Continued)
COIL
RATED
2
MODEL
CFM
CF/CM/CU48C
1400
CF/CM/CU48D
1400
CF/CM/CU60C
1400
CF/CM64D
1400
CF/CM/CU48C
1400
CF/CM/CU48D
1425
CF/CM/CU60C
1400
CF/CM64D
1400
CF/CM/CU48C
1325
CF/CM/CU60C
1325
CF/CM/CU48C
1575
CF/CM/CU48D
1600
CF/CM/CU60C
1575
CF/CM/CU60D
1600
CF/CM64D
1575
CF/CM/CU48C
1450
CF/CM/CU48D
1475
CF/CM/CU60C
1450
CF/CM/CU60D
1475
CF/CM64D
1450
CF/CM/CU48C
1300
CF/CM/CU48D
1300
CF/CM/CU60C
1575
CF/CM/CU60D
1300
CF/CM64D
1300
CF/CM/CU48C
1425
CF/CM/CU48D
1450
CF/CM/CU60C
1425
CF/CM/CU60D
1450
CF/CM64D
1425
CF/CM/CU48C
1300
CF/CM/CU48D
1300
CF/CM/CU60C
1300
CF/CM/CU60D
1325
CF/CM64D
1300
CF/CM/CU48C
1425
CF/CM/CU48D
1450
CF/CM/CU60C
1425
CF/CM/CU60D
1300
CF/CM64D
1425
CF/CM/CU48D
1425
CF/CM/CU60D
1450
CF/CM64D
1425
CF/CM/CU48C
1425
CF/CM/CU48D
1425
CF/CM/CU60C
1425
CF/CM/CU60D
1425
CF/CM64D
1425
CF/CM/CU48C
1425
CF/CM/CU48D
1425
CF/CM/CU60C
1425
CF/CM/CU60D
1425
CF/CM64D
1425
COOLING
NET MBH
SEER
TOTAL
SENS.
46.5
34.8
13.50
46.5
34.8
13.50
46.5
34.0
13.75
47.0
34.6
14.00
47.0
35.2
13.75
47.0
35.2
13.75
47.0
34.6
14.00
47.5
35.0
14.25
46.5
33.8
13.25
47.0
33.8
13.25
46.5
34.6
13.00
46.5
34.8
13.00
47.0
36.0
13.50
47.0
36.4
13.50
47.5
36.8
14.00
47.0
35.6
14.00
47.0
35.8
14.00
47.5
35.2
14.00
47.5
35.6
14.00
47.5
35.6
14.75
47.0
33.8
14.00
47.0
33.8
13.75
47.0
36.0
13.50
47.5
34.0
14.00
47.5
34.4
14.75
47.0
35.2
14.00
47.0
35.6
14.00
47.5
35.2
14.00
47.5
35.4
14.00
47.5
35.4
14.75
47.0
33.8
14.00
47.0
33.8
14.00
47.5
34.0
14.00
47.5
34.2
14.00
47.5
34.4
14.75
47.0
35.2
14.00
47.0
35.6
14.00
47.5
35.2
14.00
47.5
34.0
14.25
47.5
35.4
14.75
47.0
35.2
14.00
47.5
35.4
14.25
47.5
35.4
14.75
46.5
34.8
13.75
47.0
35.2
13.75
47.0
35.2
14.00
47.0
35.0
14.00
48.0
35.8
14.25
46.5
34.8
13.75
47.0
35.2
13.75
47.0
35.2
14.00
47.0
35.0
14.00
48.0
35.8
14.25
Johnson Controls Ducted Systems
EER
11.50
11.50
11.50
11.75
11.75
11.75
12.00
12.00
11.25
11.25
11.25
11.00
11.50
11.50
11.75
12.00
12.00
12.00
12.00
12.25
12.00
11.75
11.50
11.75
12.25
12.00
12.00
12.00
12.00
12.25
12.00
12.00
12.00
12.00
12.25
12.00
12.00
12.00
12.00
12.25
12.00
12.00
12.25
11.75
11.75
11.75
11.75
12.00
11.75
11.75
11.75
11.75
12.00

Advertisement

Table of Contents
loading

Table of Contents