3.2 Extra lubrication

Extra lubrication can be launched by pressing the Extra lubrication button located on the cover
Led signal Power. Lubrication is launched, if the center is not currently pressurizing the system,
in alarm mode or turned off.
In dual line grease lubrication system (SG2) both lines are pressurized once. In automatic
pressurization mode, the first line is pressurized first.
In single channel grease lubrication system (SG1) the line is pressurized twice.
In grease lubrication systems (SG1 and SG2)
the line equipped with a pressure switch has a delay between pressurization phases.
Phase code Ed is displayed in value display and time display shows the delay time left
the second pressurization phase in pressure transmitter operation is started, when the
pressure in the lines goes below the set low limit value. Value display shows waiting time
phase code dC and time display indicates the pressure discharge time spent.
In oil lubrication systems (OS) line is pressurized once.
Interval counter is reset when the last pressurization is started which means that the next
automatic mode pressurization is performed always according to lubrication cycle after extra
lubrication.

3.3 Manual control

Manual control mode can be transferred into by selecting the phase code HL into the value
display with the arrow buttons and by pressing Settings/Pressure button after that. Then value
display shows code HL and time display shows time 0.00; line and pump controls have not
been connected.
Note
Manual control mode can be browsed with buttons
display is run by pressing Settings/Pressure button.
Table 2.
Time display code
L1
L2
LOFF
PU-S
PU-F
POFF
OFF
Note
110i1CEN.doc
It is not possible to transfer into manual control mode, if pressurization is
being performed currently or center has triggered a low limit alarm.
Manual control mode functions
Function
line 1 line control connection
line 2 line control connection
line control disconnection
pump start-up through switch control
pump start-up, forced
pump off function
transferring out of manual control mode
Oil lubrication system can use only forced control.
SAFEGREASE, SAFEOIL
ST-1100i
and
. The selected function at the
7 (14)
16.04.2003 Rev. 1C