Pressure discharge
In pressure transmitter operation, line pressure discharge is measured and new pressurization
can be started only after pressure in all lines is below the set low limit value.
When center is waiting for pressure discharge completion, there is a phase dC in the value
display and time display shows the spent discharge time. Center goes into alarm mode, if the
discharge time is longer than interval time (= lubrication time/2).

3.1.2 Normal mode displays

Buttons
program set values and to transfer into manual control.
Value display codes change in the following order when
when
Display codes
HL
CC
LC
LP
Ld
Lo
Hi
LF
PU
Pr
PASS
110i1CEN.doc
and
can be used to browse the normal mode displays which show the lubrication
-button is pressed.
Description
Manual mode
(Hand Lubrication)
Lubrication cycle counter
(Cycle Counter)
Lubrication cycle set value
(Lubrication Cycle)
Maximum pressurization time set value
(Lubrication, Pressurization time)
Lubrication delay time, total duration
(Lubrication delay)
Code is used only in pressure switch operation
Low limit pressure set value
(Low limit pressure)
Code is used only in pressure transmitter operation
High limit pressure set value
(High limit pressure)
Code is used only in pressure transmitter operation
Center function mode (configuration settings)
(Lubrication, Function)
Pressure display unit (configuration settings)
(Pressure Unit)
Pressure monitoring unit (configuration settings)
(pressure switch operation/pressure transmitter operation)
(Pressure monitoring unit)
Entering password
(PASSword)
Code shows in time display
SAFEGREASE, SAFEOIL
ST-1100i
-button is pressed and vice versa,
5 (14)
16.04.2003 Rev. 1C