Technical Specifications; Technical Data - SAFEMATIC ST-1100i Manual

Control center for safegrease, safeoil
Table of Contents

Advertisement

5 TECHNICAL SPECIFICATIONS

5.1 Technical data

Value
t
U
in
U
out
F1
F2
F3
Time settings
Lubrication cycle value can be set within 0 min 00 s – 9999 min.
Maximum pressurization time can be set within 0 min 00 s - 999 min.
All time settings are password-protected.
Power failure protection
Set values and program status at the power failure are stored in the EEPROM memory, no
batteries.
110i1CEN.doc
Range
-20...+60
230 ±15%, 50/60
115 ±15%, 50/60
24
1 (230)
2 (115)
5
2
200 x 300 x 120
(lxkxs)
IP65
SAFEGREASE, SAFEOIL
ST-1100i
Unit
Description
°C
operation temperature
V AC, Hz
Power input, 160 VA max.
V AC, Hz
Voltage range preset at factory and indicated in
the center name plate.
V DC
Control voltage, unregulated 5 A max.
The internal power supply for controlling the
system.
AT (V AC)
Power input fuse, 20x5 mm glass tube fuse, slow
AT (V AC)
AT
Control voltage fuse, 24 V for I/O-voltage, 20x5
mm glass tube fuse, slow
AT
Electronic system fuse, 15 V, 20x5 mm glass
tube fuse, slow
mm
Steel casing
Protection classification
13 (14)
16.04.2003 Rev. 1C