Specifications - Daikin VRV Series Engineering Data

Outdoor air processing unit 60 hz r-410a
Hide thumbs Also See for VRV Series:
Table of Contents

Advertisement

FXMQ-MFVJU

2. Specifications

Model
Power supply
H1, H3 Cooling capacity
H2, H3 Heating capacity
Casing / Color
Dimensions: (H × W × D)
Rows × Stages × Fin pitch
Coil (cross
fin coil)
Face area
Model
Type
Motor output ×
Number of units
Fan
Airflow rate
External static
pressure
Drive
Temperature control
Sound absorbing thermal insulation
material
Air filter
H6 Sound pressure level
(reference data)
Weight
Liquid pipes
Piping
Gas pipes
connections
Drain pipe
Safety devices
Refrigerant control
H5 Connectable outdoor units
Standard accessories
Note:
H1. Nominal cooling capacities are based on the following conditions:
Outdoor temperature: 91°FDB, 82°FWB (68%RH)
Discharge set temperature: 64°FDB
Equivalent refrigerant piping length: 25 ft (horizontal)
H2. Nominal heating capacities are based on the following conditions:
Outdoor temperature: 32°FDB, 27°FWB (50%RH)
Discharge set temperature: 77°FDB
Equivalent refrigerant piping length: 25 ft (horizontal)
H3. Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
H4. Air filter is not standard accessory, but please mount it in the duct system of the suction side.
Select its duct collection efficiency (gravity method) 50% or more.
H5. Within the range that the total capacity of indoor units is 50 to 100%, it is possible to connect to the outdoor unit.
H6. Anechoic chamber conversion value, measured under JIS conditions. During actual operation, these values may be higher as a result of
installation conditions.
FXMQ48MFVJU
1 phase, 60 Hz, 208/230 V
Btu/h
48,000
Btu/h
30,000
Galvanized steel plate
in.
18-1/2 × 29-1/4 × 43-5/16
3 × 26 × 13
ft²
D13/4G2DA1
Sirocco fan
W
380 × 1
cfm
in. H2O
Direct drive
Microprocessor thermostat for cooling and heating Microprocessor thermostat for cooling and heating
Glass fiber
dBA
lbs
in.
ɸ3/8 (flare connection)
in.
ɸ5/8 (flare connection)
in.
PS1B
Fuse, Thermal protector for fan motor
Electronic expansion valve
R410A VRV series
Operation manual, Installation manual, Sealing
pads, Screws, Clamps
3.01
635
0.88
H4
43
190
Operation manual, Installation manual, Sealing
3
EDUS39-900B-F10
FXMQ72MFVJU
1 phase, 60 Hz, 208/230 V
72,000
47,000
Galvanized steel plate
18-1/2 × 54-3/8 × 43-5/16
3 × 26 × 13
7.00
D13/4G2DA1
Sirocco fan
380 × 1
988
0.96
Direct drive
Glass fiber
H4
48
271
ɸ3/8 (flare connection)
ɸ3/4 (brazing connection)
PS1B
Fuse, Thermal protector for fan motor
Electronic expansion valve
R410A VRV series
pads, Screws, Clamps, Connection pipes
C: 3D065463

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vrv fxmq-mfvjuFxmq48mfvjuFxmq72mfvjuFxmq96mfvju

Table of Contents