Installation manual 1 Safety Precautions This appliance can be used in public areas. Remove all objects from pockets such as lighters and matches. WARNING. This appliance is intended only for drying textiles washed in water. DO NOT MODIFY THIS APPLIANCE. Servicing shall be carried out only by authorized personnel.
Installation manual 2 Technical data fig.W01350 1805 1805 1560 1885 1325 Air outlet Exhaust air connection ⌀ 200 mm, maximum permitted pressure drop 70 Pa, which corresponds to a straight pipe with a length of approx. 23 m. Net weight: 175 kg. Connections ⌀...
Installation manual 3 Delivery The cabinet is delivered unassembled on a transport unit. The cabinet component is assembled as instructed in this manual. The electric fan heater is fully assembled upon delivery. 3.1 Transport unit The transport unit contains 5 boxes with the content described below. 1950 200 kg 1040...
Installation manual 3.4 Placement The drying cabinet intended for placement indoors in dry place. Place the bottom plate in the final position of the drying cabinet. The drying cabinet should be positioned so that there is plenty of room for working, both for the user and service personnel.
Installation manual 4.11 Fan heater fig.W01343 Bag / Quantity Box 1 M6x10 Bracket Right Bracket Left M6x10 Seal Left Upper Seal Right Lower...
Page 23
Installation manual fig.W01344 To prevent malfunctions and optimize the drying process, the fan heater must be installed in such a way that there is a gap of approx. 15 mm between the fan heater and the side of the cabinet. fig.W01345 approx.
Page 25
Installation manual The electrical box contains electronics and moisture sensors that control the drying process and turns off the appli- ance when the laundry is dry. The electrical box is installed on the left side of a cabinet in left-mounted door version on the right side for a right- mounted door version.
Installation manual 6 Evacuation system 6.1 Fresh air The drying cabinet has an exhaust air flow of up to 400 cubic meters per hour. This air is initially taken from the room where the drying cabinet is situated. It is therefore important to ensure that fresh air can enter the room from the outside to replace the humid air that is vented out.
Installation manual 6.3 Multiple cabinets If multiple drying cabinets or dryers are connected to the same air duct, a non-return valve must be installed on each appliance to prevent cold air from entering or the air pressure of one appliance affecting the other. fig.W01349 Number of cabinets...
Installation manual 7 Electrical connection The electrical installation may only be performed by qualified personnel. Electrical connection of the cabinet must be done in accordance with electrical safety regulations. Make sure that the connection current is in line with the data on the identification plate and that the mains cable is grounded properly according to the applicable standard.
Page 30
Installation manual Use the program buttons to move to Parameter 117, and enter the parameter using the Stop button. Select the baud rate that matches the setting in ELS Vision: 0: off, 1: 2400 bps, 2: 4800 bps, 3: 9600 bps. Use the Stop button to exit the parameter.
Installation manual 8 Function check May only be performed by qualified personnel. A function check must be performed when the installation is finished and before the appliance can be used. Whenever a repair has been made, a function check must be performed before the appliance can be used again. •...
Installation manual 9 Disposal information 9.1 Disposal of appliance at end of life Before disposing of the machine, make sure to carefully check its physical condition, and in particular any parts of the structure that can give or break during scrapping. The machine’s parts must be disposed of in a differentiated way, according to their different characteristics (e.g.
Page 36
Electrolux Professional AB 341 80 Ljungby, Sweden www.electroluxprofessional.com...